ViewPoint 8650C
User Guide
2 Installation Guide
Issue 10 (2013-07-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
24
The device surface is clean, and all parts are in good condition.
The ESD wrist strap is inserted into the chassis ESD jack.
Verifying Cable Connection
Verify the following cable connection items:
All cables, including the power and ground cables, are connected to the device securely
and correctly.
Cable ties do not overlap, and the cuts are neat without burrs.
Excessive parts of power and ground cables are cut instead of being twisted up.
Power and ground cable labels (including power switch labels) are correctly filled in and
consistently attached. If possible, attach the labels 20 mm (0.79 in.) away from the cable
connectors.
The power and ground cables are 30 mm (1.18 in.) away from the signal cable outside
the cabinet.
Verifying Power Supply
Ensure that the performance of the external AC power supply meets the requirements.
2.3.2 Powering On the MCU
Procedure
Step 1
Use the power cable to connect the AC power module of the MCU to the power socket on the
wall.
Step 2
Switch on the power switch of the MCU.
Figure 2-3
AC power supply
----End
Result
After the MCU is connected to the power supply, the indicators on the front panel of boards of
the MCU start to fast blink. After the MCU is powered on, the RUN indicator becomes slow
blinking.