Step 2
Power off the server. For details, see
Step 3
Remove the power cables. For details, see
3.7 Removing Cables from a PSU
.
Step 4
Remove the server. For details, see
3.3 Removing the Server and Guide Rails
.
Step 5
Remove the chassis cover. For details, see
3.4 Removing the Chassis Cover
.
Step 6
Remove the riser card tray where the RAID controller card is to be installed. For details, see
3.12 Removing a Riser Card Tray
Step 7
Take a spare Avago SAS3004iMR RAID controller card out of the ESD bag.
Step 8
Install the Avago SAS3004iMR RAID controller card. For details, see
.
Step 9
Install the riser card tray. For details, see
3.13 Installing a Riser Card Tray
.
Step 10
Install the M.2 SSD modules on the Avago SAS3004iMR RAID controller card. For details,
see
.
Step 11
Install the chassis cover. For details, see
3.5 Installing the Chassis Cover
Step 12
Install the server. For details, see
4.4 Installing the Server on Guide Rails
.
Step 13
Connect the power cables. For details, see
Step 14
Power on the server. For details, see
Step 15
Log in to the iBMC WebUI, and check whether the new component is normal. For details, see
the
Huawei Rack Server iBMC User Guide
----End
5.10 M.2 SSD Module
To install an M.2 SSD module, perform the following steps:
Step 1
Wear an ESD wrist strap. For details, see
12 Preventing Electrostatic Discharge
.
NOTE
M.2 SSD modules support hot swap. You do not need to power off the server when installing an M.2
SSD module.
Step 2
Take an M.2 SSD module out of its ESD bag.
Step 3
Open the handle that secures the M.2 SSD module, push the module into a slot in the Avago
SAS3004iMR RAID controller card, and close the handle. See
.
2288H V5 Server
User Guide
5 Optional Part Installation
Issue 04 (2018-09-04)
Copyright © Huawei Technologies Co., Ltd.