If the PSUs are properly installed and connected to the external power supply and the
server is in the standby state (the power indicator is steady yellow), power on the server
as follows:
–
Press the power button on the front panel to power on the server. For details about
the power button position, see
2.2 Front Panel Indicators and Buttons
–
Power on the server using the iBMC WebUI.
i.
Log in to the iBMC WebUI. For details, see
.
ii.
Choose
Power
>
Power Control
.
The
Power Control
page is displayed.
iii. Click
Power On
. In the displayed dialog box, click
Yes
to power on the server.
–
Power on the server using the Remote Virtual Console.
i.
Log in to the Remote Virtual Console. For details, see
ii.
On the KVM screen, click
or
on the menu bar.
iii. Choose
Power On
.
A dialog box is displayed.
iv. Click
Yes
to power on the server.
–
Power on the server using the iBMC CLI.
i.
Log in to the iBMC CLI. For details, see
14.3 Logging In to the iBMC CLI
.
ii.
On the iBMC CLI, run the
ipmcset -d powerstate -v 1
command.
iii. Enter
y
or
Y
to power on the server.
3.2 Powering Off the Server
NOTE
l
Services and programs running on the server will be interrupted when it is powered off. Before
powering off the server, ensure that all services and programs have been stopped or switched to
other servers.
l
The power-off described in this section the server to the standby state (the power indicator is steady
yellow).
l
After the server is powered off forcibly, wait for more than 10s to ensure that the server is powered
off completely. Then you can power it on again.
Power off the server using one of the following methods:
l
Use cables to connect the server to a video display, keyboard, and mouse, and shut down
the server OS to power off the server.
l
Press and hold down the power button on the front panel until the server is powered off.
For details about the power button position, see
2.2 Front Panel Indicators and
l
Power off the server using the iBMC WebUI.
a.
Log in to the iBMC WebUI. For details, see
b.
Choose
Power
>
Power Control
.
2288H V5 Server
User Guide
3 Basic Operations
Issue 04 (2018-09-04)
Copyright © Huawei Technologies Co., Ltd.
41