the faults and ensure that the peer AG can be pinged from the MA5612 and that there is no packet
loss. Then, check whether the service is restored.
l
If the service is restored, go to
l
If the service is not restored, go to
.
Step 10
Run the
dsp attribute
command on the MA5612 to change the static initial jitter buffer value
(the
normal-fixed-jb
parameter) of the DSP channel to double the packetization duration. (The
packetization duration can be queried on the MGC.) Then, check whether the service is restored.
l
If the service is restored, go to
l
If the service is not restored, go to
.
Step 11
Record the results of the preceding steps in a fault report (see Fault Report Form), fill out the
entire form, and then submit it to Huawei for technical support (see
Step 12
End.
----End
SmartAX MA5612 Multi-service Access Module
Maintenance Guide
5 Troubleshooting Services Transmitted Through a GPON
Port
Issue 01 (2012-07-25)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
198