Figure 3-4
Diameter of a pole
CAUTION
l
The diameter of a pole for installing an RRU ranges from 60 mm (2.36 in.) to 114 mm (4.49
in.). The recommended diameter is 80 mm (3.15 in.).
l
If the diameter of a pole ranges from 60 mm (2.36 in.) to 76 mm (2.99 in.), a maximum of
two RRUs can be installed on the pole and the side-mounted installation is not recommended.
shows an RRU installed on a pole.
Figure 3-5
RRU installed on a pole
Installing an RRU on U-steel
shows U-steel specifications.