Fiber optic cables are used within the temperature range of -40°C to 60°C. If the current
temperature is out of the range, make protection measures or route the cables again.
l
Cables are routed in an untangled and orderly fashion.
l
Do not bind fiber optic cables at turns.
l
Do not stretch, step on, or place heavy objects on fiber optic cables. Keep the cables away
from sharp objects.
l
When fiber optic cables are routed, the excess of the cables must be coiled around special
devices, such as a fiber coiler.
l
When coiling fiber optic cables, apply even strength. Do not bend the cables with force.
l
Vacant optical connectors must be covered with dustproof caps.
l
Fiber optic cables cannot be squeezed by the cabinet door when routed through the cabinet,
as shown in
Figure 9-4
CPRI fiber optic cables routed through the cabinet (1)
Figure 9-5
CPRI fiber optic cables routed through the cabinet (2)