Figure 3-9
Angle steel specifications
CAUTION
l
It is recommended that only one RRU be installed on angle steel.
l
The vertical deviation angle of angle steel must be less than or equal to 10 degrees, as shown
in
shows an RRU installed on angle steel.
Figure 3-10
RRU installed on angle steel
Installing an RRU on a Wall
The wall on which RRUs are installed must meet the following requirements:
l
When a single RRU is installed, the wall has a capacity of bearing at least four times the
weight of the RRU.
l
Expansion bolts must be tightened to 30 N·m (265.52 lbf·in.) to ensure the bolts work
properly and the wall remains intact without cracks in it.
RRU3232
Installation Guide
3 Information About the Installation
Issue 05 (2011-10-20)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15