Figure 5-57
Removing an unshielded Ethernet connector
----End
Installing Fiber Connectors
Context
After you remove the dustproof cap, ensure that the fiber pins are clean and install them as
soon as possible.
When you disassemble fiber connectors, you must use a dedicated tool if the connectors
are densely installed.
Cleaning Fiber Connectors
Procedure
Step 1
Clean the pins of a fiber connector by using lint-free cotton and alcohol.
Step 2
Clean the pins again by using dust-free cotton. If necessary, clean the pins by using an air gun.
Ensure that the pins are free from any fiber or debris.
----End
Installing an FC Fiber Connector
Procedure
Step 1
Remove the dustproof cap of the FC connector and store it for future use.
Step 2
Align the core pin of the male connector with that of the female connector, as shown in Figure
5-58.