Connecting Cables to a Power Cable Connector
Obtaining Tools, Cables, and a Power Cable Connector
1
37
Appendix
Ruler
(optional)
Diagonal pliers
Utility knife
Phillips
screw driver
(M3 screw )
One 0 V black ground cable
One -48 V blue pow er cable
Pow er cable connector
Peeling Cables
2
Use the 1:1 peeling indicator on
one side of the pow er cable
connector as the peeling length
reference.
1
Peeling length
reference plane
Use a pair of diagonal pliers to trim off one end of
a -48 V pow er cable. Place the cable on the
peeling length reference plane, and use a utility
knife to make a mark on the cable according to
the 1:1 peeling indicator.
2
12 mm
1:1 peeling indicator (12 mm)
3
Peel the cable using
the diagonal pliers.
12 mm
Cable core
4
Repeat steps 1-3 to peel a 0 V ground
cable.
Note
If a ruler is available, you can use the ruler to measure a 12 mm
peeling length after trimming off one end of a cable.
12 mm
Cable core
1:1 peeling indicator (12 mm)
12 mm