5.3 Operating and Storage Temperatures and Humidity
Table 5-2 lists the operating and storage temperatures and humidity for the MU736
module.
Table 5-2
operating and storage temperatures and humidity for the MU736 module
Specification
Min.
Max.
Unit
Normal working temperatures
[1]
–10
+55
°C
Extended temperatures
[2]
–20
+70
°C
Ambient temperature for storage
–40
+85
°C
Moisture
5
95
%
[1]: When the MU736 module works at this temperature, all its RF indexes comply with the
3GPP TS 45.005 specifications.
[2]: When the MU736 module works at this temperature,
NOT
all its RF indexes comply with the
3GPP TS 45.005 specifications.
5.4 Electrical Features of Application Interfaces
Table 5-3
Electrical features of Digital Pins
Parameter
Description
Min.
Max.
Unit
BodySAR_N
V
IH
1.26
3.6
V
V
IL
–0.2
0.3
V
RESET
V
IH
1.26
2.1
V
V
IL
–0.2
0.3
V
Power_On_Off
V
IH
1.26
3.6
V
V
IL
–0.2
0.3
V
W_DISABLE
V
IH
1.26
3.6
V
V
IL
–0.2
0.3
V
GPS_DISABLE
V
IH
1.26
3.6
V
V
IL
–0.2
0.3
V
SIM_DET
V
IH
1.26
2.1
V
V
IL
–0.2
0.3
V