background image

 

Step 2

 

Enter a new IP address as desired in the 

IP Address

 text box. Then, enter a 

subnet mask in 

Subnet Mask

Step 3

 

Click 

Submit

 to save the settings. 

 

To log in to the Web-based configuration utility after you change the IP 

address successfully, you need to launch the Internet Explorer, and then 

enter the new IP address in the address bar. Ensure that the IP address of 

the computer is in the same network segment as that of the MT886 so that 

the computer can access the Web-based configuration utility. 

4.3 

Restoring Default Settings 

You can quickly restore the default settings of the MT886 by pressing the RESET 

button on the rear panel. To restore the default settings, press and hold the RESET 

button for over six seconds after the MT886 is powered on, and then release the button. 

In addition, you can restore the default settings of the MT886 through the Web-based 

configuration utility. To restore the default settings through the Web-based 

configuration utility, do as follows: 

Step 1

 

Log in to the Web-based configuration utility, and then choose 

Tools

 > 

Reboot

 in the navigation tree to display the reboot page. 

Step 2

 

Select 

Factory Default Settings

Step 3

 

Click 

Restart

After the preceding operations, the page jumps to the login page. You can log in to the 

Web-based configuration utility by entering the default user name and password. 

FAQs 

How can I quickly restore the default settings of the terminal? 
To restore the default settings, press and hold the RESET button on the rear panel for 

over six seconds after the MT886 is powered on, and then release the button. 
What can I do if I cannot access the Internet through the terminal? 

Step 1

 

Check whether the POWER indicator on the terminal is solid on. 
If the POWER indicator is off, perform further checks as follows: 
1.

 

Ensure that the terminal is turned on. 

2.

 

Ensure that electricity comes from the socket and that the power input 

from the socket meets the requirements described on the label of the 

terminal power adapter. If the voltage is unsteady, for example, if the 

voltage is too high or too low, do not use the terminal. Wait until the 

voltage restores to its normal level, and then use the terminal. 

Summary of Contents for MT886

Page 1: ...MT886 ADSL CPE User Guide HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...provides customers with comprehensive technical support and service Please feel free to contact our local office or company headquarters Huawei Technologies Co Ltd Address Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China Website http www huawei com Email terminal huawei com ...

Page 3: ...ted or may be limited by local network operators or network service providers Thus the descriptions herein may not exactly match the product or its accessories you purchase Huawei Technologies Co Ltd reserves the right to change or modify any information or specifications contained in this manual without prior notice or obligation NO WARRANTY THE CONTENTS OF THIS MANUAL ARE PROVIDED AS IS EXCEPT A...

Page 4: ...86 4 3 2 Accessing the Network Through the PPP Dial up Software on Your Computer 5 4 Configuring the MT886 6 4 1 Changing the Administrator Password Used for Logging In to the Web Based Configuration Utility 6 4 2 Changing the IP Address Used for Logging In to the Web Based Configuration Utility 6 4 3 Restoring Default Settings 7 5 FAQs 7 6 Appendix 10 6 1 Indicators 10 6 2 Interfaces and Buttons ...

Page 5: ...disconnect it from the power supply Ensure that your hands are dry during operation Keep the device far from sources of heat and fire such as a heater or a candle Keep the device far from electronic appliances that generate strong magnetic or electric fields such as a microwave oven or a refrigerator Place the device on a stable surface Place the device in a cool and well ventilated indoor area Do...

Page 6: ...EC60950 1 EN60950 1 and it is tested and approved according to national or local standards For pluggable device the socket outlet shall be installed near the device and shall be easily accessible Safety of Children Keep the device and its accessories out of the reach of children Otherwise they may damage the device and its accessories by mistake or they may swallow the small components of the devi...

Page 7: ...itter 5 Telephone jack on the wall 2 2 Getting Started To power on the MT886 press the power button on the top of the MT886 After you power on the MT886 the ADSL indicator blinks for less than three minutes which indicates that the MT886 is being activated Later the ADSL indicator turns solid on The POWER indicator is also solid on which indicates that the MT886 is working properly ...

Page 8: ...rer on your computer Enter http 192 168 1 1 in the address bar and then press Enter 2 In the displayed dialog box enter the user name and the password and then click OK By default the user name is admin and the password is admin After the user name and the password are verified you can access the Web based configuration utility Step 2 Enable the embedded dial up function 1 In the navigation tree o...

Page 9: ...tems To create a dial up connection do as follows taking the Windows XP operating system as an example 1 Choose Start All Programs Accessories Communications Network Connections 2 Click Create a new connection in Network Tasks to display the New Connection Wizard window and then click Next 3 Select Connect to the Internet and then click Next 4 Select Set up my connection manually and then click Ne...

Page 10: ...ettings After you change the password successfully the current page jumps to the page for logging in to the Web based configuration utility To log in to the Web based configuration utility enter the new password and then click OK If you forget the password that has been changed you can restore the default settings of the MT886 by pressing and holding the RESET button for over six seconds Then the ...

Page 11: ...ows Step 1 Log in to the Web based configuration utility and then choose Tools Reboot in the navigation tree to display the reboot page Step 2 Select Factory Default Settings Step 3 Click Restart After the preceding operations the page jumps to the login page You can log in to the Web based configuration utility by entering the default user name and password 5 FAQs How can I quickly restore the de...

Page 12: ... cable between the terminal and the computer is properly connected Remove and then insert the network cable or replace the network cable when necessary If the LAN indicator is still off contact an authorized maintenance center Step 4 Check whether the driver for the network adapter is properly installed Take a computer that runs Windows XP as an example To check whether the driver for the network ...

Page 13: ...xy server group box of the Local Area Network LAN Settings dialog box ensure that the Use a proxy server for your LAN These settings will not apply to dial up or VPN connections check box is cleared Step 8 Try to access multiple Web sites to check whether the terminal can access these Web sites If the terminal still cannot access Web sites contact your network service provider What can I do if Web...

Page 14: ...out degrading call quality or lowering the Internet access rate 6 Appendix 6 1 Indicators Indicator Status Description POWER Solid on The MT886 is powered on Off The MT886 is powered off ADSL Blinking The MT886 is being activated Solid on The MT886 is activated Off The MT886 is powered off LAN1 LAN2 Blinking Data is being transmitted through the Ethernet interface Solid on The Ethernet connection ...

Page 15: ...255 0 User name used for logging in to the Web based configuration utility admin Password used for logging in to the Web based configuration utility admin DHCP server function Enable 6 4 Technical Specifications Item Specification Ambient temperature for operation 0 C to 40 C 32 F to 104 F Relative humidity for operation 5 to 95 non condensing Dimensions L W H 118 4mm 40 4mm 90 3mm Weight About 11...

Page 16: ...12 Item Specification DSL transmission rates G dmt T1 413 Maximum downlink rate 8 Mbit s Maximum uplink rate 896 Kbit s G 992 5 ADSL2 Maximum downlink rate 24 Mbit s Maximum uplink rate 1024 Kbit s ...

Page 17: ...HUAWEI TECHNOLOGIES CO LTD Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Republic of China www huawei com Part Number 103178 ...

Reviews: