![Huawei MG301 Hardware Manual Download Page 32](http://html.mh-extra.com/html/huawei/mg301/mg301_hardware-manual_167892032.webp)
35
HUAWEI MG301 B2B Module
HardwareGuide
Electrical and Reliability Features
5
Electrical and Reliability Features
5.1
About This Chapter
This chapter describes the electrical and reliability features of the interfaces in the
MG301 B2B module, including:
Extreme Working Conditions
Operating and Storage Temperatures and Humidity
Electrical Criteria of Application Interfaces
Power Supply Features
Reliability Features
ESD Features
5.2
Extreme Working Conditions
Table 5-1 lists the extreme working conditions for the MG301 B2B module. Using the
MG301 B2B module beyond these conditions may result in permanent damage to the
module.
Table 5-1
Extreme working conditions for the MG301 B2B module
Symbol
Specification
Minimum Value
Maximum Value
Unit
VBAT
External power voltage
–0.40
6.00
V
VCOIN
Input voltage of standby
power for the RTC
2.00
3.15
V
V
I
Digital pin voltage
–0.40
V
I
+0.40
V
Huawei Proprietary and Confidential Copyright ©
Huawei Technologies Co., Ltd
Issue 06 (2013-06-13)