7
GLOBAL ENERGY EFFICIENCY SPECIALIST
Parameter
Min.
Typ.
Max.
Unit
Notes & Conditions
Other characteristics
+S
-
-
5
%V
out
See Remote Sense.
-S
-
-
0.5
V
CB
0
-
3.3
V
Current sharing pin that needs to be
connected to -S
TRIM
0
-
2.5
V
Needs to be connected to -S if output
voltage adjustment is required
Input voltage precision
–10
-
10
V
T
A
= 25
°
C, V
in
= 90
–290 V AC
Insulation characteristics
Input to output insulation
voltage
-
-
4242
V DC
Reinforced insulation;
The leakage current should be less
than 10 mA. The test voltage ramp up
less than 500 V per second.
Input to baseplate insulation
voltage
-
-
3535
V DC
Output to baseplate insulation
voltage
-
-
707
V DC
Input to output insulation
resistance
10
-
-
MΩ
Normal atmospheric pressure;
90% humidity;
500 V DC
Input to baseplate insulation
resistance
10
-
-
MΩ
Output to baseplate insulation
resistance
10
-
-
MΩ
Reliability characteristics
Mean time between failures
(MTBF)
-
1.2
-
Million
hours
T
Baseplate
= 25
°
C, Telcordia SR332
Method 1 Case 3; normal input/rated
output, 80% load
Electrical Specifications
ADF10S48B
AC-DC Converter Technical Manual V1.1
Specifications are subject to change without notice.