4
GLOBAL ENERGY EFFICIENCY SPECIALIST
Parameter
Min.
Typ.
Max.
Unit
Notes & Conditions
Environment characteristics
Operating ambient temperature
(T
A
)
–40
-
85
°
C
-
Storage and transportation
temperature
–55
-
125
°
C
-
Operating and storage humidity
10
-
95
% RH
Non-condensing
Altitude
0
-
5000
m
Certified to 4000 m
Baseplate temperature
–40
-
90
°
C
Conduction cooled
Absolute maximum ratings
Input voltage (continuous)
-
-
315
V AC
-
Voltage to SCL/SDA/ADDR/CB
-
-
3.6
V
-
Number of modules for parallel
operation
-
-
2
PCS
-
Input characteristics
Operating input voltage
90
-
290
V AC
-
Rated input voltage
100
110/2
20
240
V AC
-
Maximum input current
-
-
8
A
V
in
= 90 V AC, 100% load
Inrush current
-
-
20
A
V
in
= 110 V AC
-
-
40
A
V
in
= 220 V AC
Input frequency
47
50/60
63
Hz
-
Power factor
0.95
-
-
-
T
A
= 25
°
C, V
in
= 110/220 V AC, 100%
load
Total harmonic distortion (THD)
-
-
10
%
T
A
= 25
°
C, V
in
= 110/220 V AC, P
out
=
500 W
No-load power
-
-
10
W
T
A
= 25
°
C, V
in
= 110 V AC
-
-
12
W
T
A
= 25
°
C, V
in
= 220 V AC
Standby power
-
-
5
W
T
A
= 25
°
C, V
in
= 110/220 V AC
Output characteristics
Output voltage trim range
36
-
55
V DC
The output voltage can be adjusted
by I2C or the Trim pin. Preferentially
use the Trim pin for output voltage
adjustment.
ADF10S48B
AC-DC Converter Technical Manual V1.1
Electrical Specifications