TDMUX-16 User Manual   V1.2

                           

-

11-

 

8/16 E1/T1 Ports Supported. E1 ports impendence are E1-120

 for twisted 

pair cables or 75

 for coax. The E1-120

 RJ45 sockets are default for ports. 

The E1-120

 connection cable is made with RJ45 connectors and a length of 

4-pair twisted cable. The cable is not provided with the equipment, and the user is 
responsible for making such cables in the field with length suitable for a particular 
installation. The signal definition is given in Table 3.2.2-1, and pin order is depicted 
in Fig. 3.2.2-1. Note that pin-1 and pin-2 should use the same twisted pair, so should 
pin-4 and pin-5.   
E1/T1 service can set the actual service quantity by NMS, set the exact E1 E1/T1 
channels received by local equipment from remote equipment, realizing E1/T1 
service one point to multi-point unidirectional transmission function.   

By NMS, E1ports provide local loop back and remote loop back, 8 E1 ports loop 
back can be set independently, and by the dip RA on front panel E1 indicators can 
be controlled to indicate local or remote ports LOS and AIS status. The local and 
remote loop back definition is shown as Fig 3.2.2-3: 

 

Fig 3.2.2-3 E1 loop back   

Rx

Æ

Tx can test E1/T1 connection cable, and Tx

Æ

 Rx is used to test the whole 

circuit including H0FL-ETHMUX V16 in the two endss and the link between them.   

3.2.3

 

Ethernet/optic fiber connection 

H0FL-ETHMUX V16 provides 5 standard RJ45 Ethernet interface and a LC optical 
interface for connection with the transmission network, such as wireless Ethernet 
bridge interface; or access to a local Ethernet port, such as switch and so on. Any 
Ethernet electrical interfaces can be used for Web Server or SNMP management and 
device software and hardware upgrades.   
Ethernet Optical adopts SFP integrated optical modules, marked with 

Æ

 for the 

optical signal input. marked with 

Å

  for the optical signal output. Optic fiber 

access though patch cord. Connect the plug socket when the optical module should 
be made to plug into the socket pin on the positioning of the corresponding gaps, 
and plug in place. Patch cord bending radius is no less than 50mm. Plug optical 
connector, not directly pulling fiber. Please keep the socket on the SFP protection 
plug, no plug inserted optical fiber, be sure to protect plugs, prevent dust entering.   
  

 

Note: 1. This equipment Ethernet electrical interface with the HP auto-MDIX 

feature that automatically detect network cable transmitting/receiving sequence and 
then adapting, both of MDI and MDI-X Ethernet interface, both crossover cable or 
straight cable can be used.   

Summary of Contents for H0FL-ETHMUX V16

Page 1: ...contents 1 H0FL ETHMUX V16 E1 over Ethernet Multiplexer User s Manual...

Page 2: ...contents 2 H0FL ETHMUX V16 E1 over Ethernet Multiplexer User s Manual TABLE OF CONTENTS...

Page 3: ...0 3 2 1 Power connection 10 3 2 2 E1 T1 connections 10 3 2 3 Ethernet optic fiber connection 11 4 TROUBLESHOOTING 12 4 1 E1 T1 ALARMS LED ON 12 4 2 LNK ACT LED OFF 12 4 3 READY LED DOES NOT BLINK 12 4...

Page 4: ...contents 4 6 2 E1 INTERFACE 26 6 3 10 100 1000BASE TX PORT 27 6 4 POWER 27 6 5 OPERATING CONDITION 27 6 6 DIMENSIONS 27 6 7 WEIGHT 27...

Page 5: ...ch is good for achieving higher bandwidth utilization But Ethernet technology does not provide adequate QoS for real time applications Until recently voice and data were and still are to a large exten...

Page 6: ...ocessing delay for E1 T1 channels high bandwidth usage efficiency z Resist to packet loss with PCM frame synchronization protection z User definable encapsulation packet size for different application...

Page 7: ...ely used application of H0FL ETHMUX V16 is to set up point to point wireless E1 T1 links using low cost wireless LAN bridges H0FL ETHMUX V16 can work with most LAN bridges on the market It may be nece...

Page 8: ...d in most applications This timing mode of rebuilding the E1 clock at the destination is called Adaptive Timing For applications where separate clock distribution network exists another timing mode Lo...

Page 9: ...Note master master loop back loop back Equipment A B clocks synchronous adaptive adaptive master master adaptive adaptive Equipment A B clocks plesiochronous master slave loop back adaptive adaptive a...

Page 10: ...stream and recovering the E1 clock which is the key element of the device Very sophisticated algorithm is used to ensure that the reconstructed clock will meet the stringent requirement of TDM applic...

Page 11: ...ion On connected with remote optical interface Off disconnected with remote optical interface Ethernet optical interface indicator OLOS R 1 Ethernet optical interface receiving status indication On re...

Page 12: ...interface can not receive E1 T1 Blink Ethernet interface has packet loss Off Ethernet interface has E1 T1 packet loss Blink normal Only when the 2nd dip switch is set OFF this dip settings will be val...

Page 13: ...port or anyone of GE electrical port could be used for NMS port GE electrical port adopts RJ45 socket RJ45 Ethernet socket is defined as Table 2 4 4 Ethernet optical port uses LC connector depending o...

Page 14: ...standard power cord supplied with the equipment Note that there is a 1A fuse in the 220V socket which may be replaced when burned The 48V equipment uses PPTC resetable fuse no customer replacement is...

Page 15: ...oop back Rx Tx can test E1 T1 connection cable and Tx Rx is used to test the whole circuit including H0FL ETHMUX V16 in the two endss and the link between them 3 2 3 Ethernet optic fiber connection H0...

Page 16: ...Ds PKT LOS and LOS for E1 T1 alarms LEDs When E1 T1 LOS LED is on loss of E1 T1 signal fault is detected by EthMux Possible causes include z The downstream equipment such as telephone exchange or PCM...

Page 17: ...ng Check if the default gateway IP is defined correctly Check if the local and remote IP is set correctly Check for any conflicts in IP or MAC addresses Make sure the transmission network has enough b...

Page 18: ...version software version IP address subnet mask gateway address and MAC address IP address subnet mask and gateway address could be changed manually but hardware software version and MAC address only...

Page 19: ...st definition as section 3 2 2 E1 T1 loopback setting only submit will valid but loopback settings will not be saved that is when reboot the equipment each channel of E1 T1 will under non loopback sta...

Page 20: ...10 100 1000Mbps indicate current Ethernet port speed Duplex Duplex indicate current Ethernet work mode half full Mode Auto 1000M full 100M full 100M half 10M full 10M half 6 Ethernet ports work mode c...

Page 21: ...ts Service No E1 T1 service No support at most 20 capital small letters digit and part special character input Chinese character support 2 numbers not support some special characters as input Enable E...

Page 22: ...o Ltd Huahuan 18 TDMUX 16 User Manual V1 2 Fig 5 2 3 VLAN management interface 1 VLAN configuration Fig 5 2 4 VLAN management interface 2 Ethernet port configuration Fig 5 2 5 VLAN management interfac...

Page 23: ...nfiguration Enable VLAN Yes with VLAN tag support the VLAN network with priority to guarantee E1 QoS default No no VLAN tag Priority Define users priority including 8 levels 0 7 the number is bigger t...

Page 24: ...rwise E1 T1 VLAN VID and PRI will set as default port7 VID VLAN ID support 4096 VLAN ID range 0 4095 Priority Define customer priority including 8 PRI degree 0 7 PRI is higher when this number is bigg...

Page 25: ...ut increase unnecessary bandwidth so here should set VLAN to Disable 4 In order to avoid the management failure caused by configuring VLAN it is not suggest to set VLAN tag for the managed VLAN member...

Page 26: ...d as below picture Then default parameters already recovered we need to restart Web Server Fig 5 3 3 default parameters recovery 2 Click Reboot to restart equipment default parameters will be valid 5...

Page 27: ...program file as figure 5 3 4 Note hardware program file name is H Patch software program file name is S patch can not be changed Fig 5 3 4 upgrade online 1 upload new program Step 2 select program ty...

Page 28: ...ger time and it need cold boot after upgrading 1 Upgrade Web management software Fig 5 3 5 upgrade online 1 select a file to upgrade Fig 5 3 5 upgrade online 2 operate successfully 2 Upgrade applicati...

Page 29: ...nfiguration loss Therefore users should treat it carefully Cold boot equipment new program will be valid Fig 5 3 9 upgrade online 4 select an hardware program file Click option Hardware it will pop ou...

Page 30: ...mpedance E1 120 for twisted pair cables or 75 for coax The RJ45 E1 120 are default for ports End to end delay minimum delay setting 10ms Output frequency offset adaptive timing stabilized 5 ppm Output...

Page 31: ...Half Full Duplex Adaptive Support 802 1Q MAC Uplink ports 1 1 backup supported Ethernet built in layer 2 switch function Support 802 1Q VLAN 802 1ad Q in Q 802 1p 6 4 Power AC 100V 260V 50Hz fuse 1A...

Reviews: