5
Working temperature range
NOTE:
The operating temperature range (outdoor temperature) for cooling is 18
℃
~43
℃
; Heating
temperature range for the model without electric heating belt for chassis is -15
℃
~ 24
℃
;
Heating temperature range for the model with electric heating belt for chassis is
-20
℃
~24
℃
.
Indoor side DB/WB(°C
)
Outdoor side DB/WB(°C
)
Maximum cooling
32/23
43/26
Maximum heating
27/-
24/18
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected
by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the wire by
yourself.
For the air conditioner with plug, the plug should be reachable
after finishing installation.
For the air conditioner without plug, an circuit break must be
installed in the line.
If you need to relocate the air conditioner to another place, only
the qualified person can perform the work. Otherwise, it may
cause personal injury or damage.
Select a location which is out of reach for children and far away
from animals or plants.If it is unavoidable, please add the fence
for safety purpose.
The indoor unit should be installed close to the wall.
Precautions
WARNING