Wired Controler
+7:
XK60
12
Fig.14 Sleep Curve under the COOL Mode
Under the Heat mode, the Sleep function is ON, the setting temperature range can
be 16°C, 17~20°C, 21~27°C or 28~30°C. Each of them has a different curve as shown
in Fig.15.
e.g. If the setting temperature is 22°C, the temperature will drop by 1°C in each
hour until it reaches 20°C. Then, the unit will run at this temperature
Fig.15 Sleep Curve under the HEAT Mode