5.2
Space Heating and Domestic Hot Water
The room thermostats are not connected to the Mono unit but to a motorized valve. Each room’s temperature is regulated
by the motorized valve on its water circuit. Domestic hot water is supplied from the domestic hot water tank connected to
the Mono unit. A bypass valve is required.
Figure 1-5.2: Space heating and domestic hot water
Legend
1
Outdoor unit
10
Collector (field supplied)
2
Plate heat exchanger
11
Bypass valve (field supplied)
3
Backup electric heater (customized)
12
Domestic water tank (field supplied)
4
Internal circulator pump
13
Heat exchanger coil
5
Stop valve (field supplied)
14
Immersion heater
6
User interface
FHL 1...n
Floor heating loops (field supplied)
7
Motorized 3-way valve (field supplied)
M1...n
Motorized valves (field supplied)
8
External circulator pump (field supplied)
T1…n
Room thermostats (field supplied)
9
Distributor (field supplied)
Notes:
1. The example is just for application illustration; please confirm the exact installation method according
to the installation manual.
10