Electrical Connections
Ensure correct power availability to prevent motor failure or dangerous electrical overloading. Observe
the motor nameplate for required amperage.
Do not use electric pump if ground is not connected on plug.
Minimise the length of extension cords and be sure they are of adequate wire size with ground
connections.
Extension cable should be 4mm² and maximum length 10 metres.
WARNING:
Electric motors may spark. Do not operate in an explosive atmosphere or in the presence of
conductive liquids. If using in a hazardous or explosive atmosphere ensure pump is ATEX approved or
approved to the relevant zone.
Air Connections
Ensure that you have sufficient air flow to operate your pneumatic pump. If in doubt, compare the pump
manufacturer’s recommended air flow rating prior to pressurising pump. Improper air flow may damage
the pump motor. For best results use air hoses larger than 3/4 I.D. diameter.
1. Adjust flow to one drop per 60 - 90 seconds
2. Fill half way with grade 46 hydraulic oil supplied
1. Adjust flow to one drop per 60 - 90 seconds
2. Fill half way with grade 46 hydraulic oil supplied
Use of a filter regulator lubricator (FRL) is highly recommended (pictured below).
7
AIR FLOW ON/OFF LEVER
CONDENSATION
BOWL
AUTO WATER
DRAIN PORT
OIL BOWL
OIL LUBRICATOR
ADJUSTMENT KNOB
OIL FILLER CAP
AIR ADJUSTMENT KNOB
l l
l l
l l
l
l l
l l
l l l
l l l l l l l l l
l l l
l l
l l l
l
2
4
6
8
10
0
HTL-Operating-Instructions-DS.indd 8
11/04/2017 10:15
Summary of Contents for DS Series
Page 2: ...HTL Operating Instructions DS indd 2 11 04 2017 10 15 ...
Page 28: ...28 OUTSIDE UK 44 0 1670 700 018 HTL Operating Instructions DS indd 28 11 04 2017 10 16 ...
Page 29: ...HTL Operating Instructions DS indd 29 11 04 2017 10 16 ...
Page 30: ...HTL Operating Instructions DS indd 30 11 04 2017 10 16 ...
Page 31: ...HTL Operating Instructions DS indd 31 11 04 2017 10 16 ...