Appendix 1
Notification once performing Golden cap replacement
If you perform M/B replacement, must take care for following notices:
1. If you use hot gun to replace any component or use solder iron to replace component that next
to G/C .Please use solder iron to remove golden capacitor before repairing.
Prohibit using hot
gun to remove golden capacitor to prevent damage.
2. If repaired M/B was removed G/C before repairing. Please use solder iron to change new G/C to
M/B after repaired. The condition of solder iron as bellow:
(1) The temperature of solder iron must be under 350 degree C ( for lead-in model ) , 380
degree C (for lead-free model).
(2) The heating time of solder iron must be under 5 seconds.
(3) Solder iron can not contact with the body of G/C.
(4)
Prohibit recycling use golden capacitor to product
.
Gold Cap