8. SERVICE 

8.1. WARRANTY 

CONDITIONS 

This equipment is guaranteed against material faults or production defects, in accordance 
with the general sales conditions. During the warranty period (one year), faulty parts may 
be replaced. The manufacturer reserves the right to decide either to repair or replace the 
product. In case of returning of the instrument, all transport charges must be paid by the 
customer. The instrument must be accompanied by a delivery note indicating the faults or 
reasons of returning. The returned tester must be packed in its original box. Any damage 
occurred in transit because of lack of original packaging will be debited to the customer. 
The manufacturer is not responsible for any damage against persons or things. 
Accessories and batteries are not covered by warranty. 
 
The warranty won’t be applied to the following cases: 
 

  Faults due to improper use of the equipment. 

  Faults due to combination of the tester with incompatible equipment. 

  Faults due to improper packaging. 

  Faults due to servicing carried out by a person not approved by the company. 

  Faults due to modifications made without explicit authorization of our technical 

department. 

  Faults due to adaptation to a particular application not provided for by the definition of 

the equipment or by the instruction manual. 

 
The contents of this manual cannot be reproduced in any form without our authorization. 
 

Our products are patented. Our logotypes are registered. We reserve the right to 
modify characteristics and prices further to technological developments.

 

 

8.2. SERVICE 

If the equipment doesn’t work properly, before contacting the SERVICE, test the batteries, 
the probes and change them if necessary. If the equipment still doesn’t work, make sure 
that your operating procedure complies with the one described in this manual. In case of 
returning of the instrument, all transport charges must be paid by the customer. The 
instrument must be accompanied by a delivery note indicating the faults or reasons of 
returning. The returned tester must be packed in its original box. Any damage occurred in 
transit because of lack of original packaging will be debited to the customer. 
 
 

Summary of Contents for HTA103

Page 1: ... Copyright HT ITALIA 2017 Release EN 1 00 14 09 2017 ENGLISH User manual ...

Page 2: ... 3 2 UNIT key 5 4 3 3 JKT key 5 4 3 4 MAX and MIN key 5 4 3 5 HOLD ENTER key 5 4 3 6 and keys 5 4 3 7 CAL key 6 4 3 8 Disabling Auto Power OFF 6 5 OPERATING INSTRUCTIONS 7 5 1 Temperature measurement 7 6 MAINTENANCE 8 6 1 General 8 6 2 Battery replacement 8 6 3 Cleaning 8 6 4 End of life 8 7 TECHNICAL SPECIFICATIONS 9 7 1 Characteristics 9 7 1 1 General data 9 7 2 Environmental conditions 9 7 2 1 ...

Page 3: ... instrument only as specified in this manual otherwise the protection provided by the instrument may be impaired Only the accessories supplied with the instrument guarantee compliance with the safety standards They must be in good conditions and must be replaced if necessary with identical models Do not effect measurements beyond the limits specified in this manual Check that batteries have been p...

Page 4: ... in perfect conditions However it s advisable to make a rapid check in order to detect eventual damages which may have occurred in transit Should this be the case enter immediately the usual claims with the carrier Make sure that all the accessories listed in 7 3 are contained in the package In case of discrepancies contact the dealer In case of returning of the tester please keep to the instructi...

Page 5: ...ey 8 UNIT key 9 CAL key 10 JKT key 11 ON OFF key 12 Tripod hole 13 Battery cover Fig 1 Instrument description 4 2 DESCRIPTION OF DISPLAY CAPTION 1 Probe type indication 2 Auto Power OFF APO symbol 3 Low battery indication 4 Main display 5 Measurement unit 6 MAX function active 7 MIN function active 8 HOLD function active 9 Secondary display Fig 2 Display description ...

Page 6: ...e of external probe K J or T to be connected to the instrument Cyclically the K J or T settings are displayed 4 3 4 MAX and MIN key By pushing MAX or MIN key permits to detect the Maximum or Minimum values of measured temperature The secondary display see Fig 2 part 9 shows the symbol linked to the selected function The symbol MAX for maximum value and MIN for minimum value The MAX or MIN values a...

Page 7: ...or 9 F with a 0 1 C 0 1 F resolution 4 By pushing long 3s again CAL key to save the settings and quit this mode The instrument keeps the set value after each shutdown 4 3 8 Disabling Auto Power OFF The instrument is provided with Auto Power OFF APO feature which automatically permits to switch it off after 15 minutes of idleness in order to preserve the internal battery To disable this feature fol...

Page 8: ...wn at two displays 2 Select the type of probe see 4 3 3 and the measurement unit see 4 3 2 3 Insert the connectors of the probe on input terminal respecting the polarity and see Fig 1 part 1 shown on the instrument and on the probe connector 4 The real time value of the temperature is shown on the main display see Fig 5 Fig 5 Use of the instrument for temperature measurement 5 Press HOLD ENTER key...

Page 9: ...d trained technicians must perform this operation Remove all the probes from the devices under test before replacing the battery 1 Switch off the instrument 2 Remove the temperature probe 3 Remove the battery cover see Fig 1 part 13 4 Remove the battery from the battery fastener 5 Set the new battery into battery fastener and return it to the battery case 6 Replace the battery cover 7 Use the appr...

Page 10: ...1 F 1 rdg 1 8 F T 148 F 1 rdg 0 9 F T 148 F 7 1 1 General data Mechanical characteristics Dimensions Lx W x H 190 x 65 x 45mm 7 x 3 x 2in Weight including battery 235g 8 ounces Mechanical protection IP40 Supply Battery type 1x9V alkaline NEDA 1604 IEC 6F22 JIS 006P Low battery indication symbol is displayed Battery life ca 50h backlight ON ca 210h backlight OFF Auto Power Off after 15 minutes of i...

Page 11: ...de TK101 Battery Carrying bag User manual 7 3 2 Optional accessories Type K probe for air and gas Cod TK107 Type K probe for semi solid substances Cod TK108 Type K probe for liquid Cod TK109 Type K probe for surfaces Cod TK110 Type K probe for surfaces with a 90 lead Cod TK111 ...

Page 12: ...ue to improper packaging Faults due to servicing carried out by a person not approved by the company Faults due to modifications made without explicit authorization of our technical department Faults due to adaptation to a particular application not provided for by the definition of the equipment or by the instruction manual The contents of this manual cannot be reproduced in any form without our ...