HT9020
EN - 30
5.8.
AC/AC+DC POWER AND ENERGY MEASUREMENT
CAUTION
The maximum AC/AC+DC input voltage is 1000V and the maximum
measurable AC/AC+DC current is 1000A. Do not measure voltages and
currents exceeding the limits given in this manual. Exceeding these limits
could result in electrical shocks to the user and damage to the instrument
We recommend holding the clamp respecting the safety area created by
the hand protection (see Fig. 3)
Fig. 12: AC/AC+DC power measure on Single phase and balanced Three phase systems
1. After positioning the selector switch to “
W
”, the screen
aside will appear.
Mod Par Fnc
Zro
A C < 1 0 . 0 H z
- - - -
k W
- - - -
k V a r i
- - - -
k V A
1 P
2. Press
F1
(
Mod
) to open the drop-down menu shown on the
screen aside and select the “
AC 1P
” (Single phase
measurement) or “
AC 3P
” (balanced Three phase
measurement) options with the same key. The “
1P
” or
“
3P
“symbols are displayed.
3. Press
F4
(
OK
) to confirm
Mod
Par Fnc
OK
A C < 1 0 . 0 H z
- - - -
k W
- - - -
k V a r i
- - - -
k V A
AC 1P
AC 3P
DC
Help