HT Italia XL421 User Manual Download Page 15

 

 

XL421 - XL422 

 

 

10.3 ACCESSORIES 

Description Code 

Adhesive Velcro 50 x 70 cm 

VELCRO 

Carrying bag 

BORSA2000 

Management software 

DATALINK 

Serial cable 

C2004 

Batteries GP15AU 
User’s manual 

YAMUM0009HT0 

 

11 SERVICE 

11.1 WARRANTY CONDITIONS 

This equipment is guaranteed against any material fault or manufacturer’s defect, in 
accordance with the general conditions of sale. During the warranty period (one year), 
faulty parts may be replaced, with the manufacturer reserving the right to decide either to 
repair or replace the product. 
In the event of returning the equipment to the after-sales service or to a regional branch, 
the outward transport is to the charge of the customer. The returning must be agreed in 
advance with the supplier or local distributor. A report indicating the reasons for returning 
and defects detected must accompany the instrument.  
The manufacturer will not be responsible for any damage against persons or things. 
The warranty doesn’t apply to the following cases: 

  Accessories and batteries (not covered by warranty). 

  Improper use of the equipment or combination of the instrument with incompatible 

equipment. 

  Damages caused by incorrect shipping procedures. 

  Damages caused by repair/service trials of unauthorized people. 

  Modifications to the equipment without explicit authorization of our Technical Dept. 

  Adaptation to a particular application not provided for by the definition of the equipment 

or by the instruction manual. 

The contents of this manual may not be reproduced in any form whatsoever without our 
agreement. 
 

NOTE: 

Our products are patented. The logotypes are registered. We reserve 
the right to modify characteristics and prices as part of technological 
developments which might require them.

 

 

11.2 AFTER-SALE SERVICE 

If the equipment doesn’t work properly, before contacting our Service Dept. please test the 
battery condition and replace them whether necessary. If the problem persists check if 
your operating procedure agrees with the one described in this manual. 
In the event of returning the equipment to the after-sales service or to a regional branch, 
the outward transport is to the charge of the customer. The returning must be agreed in 
advance with the supplier or local distributor. A report indicating the reasons for returning 
and defects detected must accompany the instrument. The manufacturer will not be 
responsible for any damage against persons or things. 
 

 

EN - 14

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for XL421

Page 1: ...ENGLISH User s manual Copyright HT ITALIA 2007 Release EN 1 02 13 06 2007 www com information itm com 1 800 561 8187...

Page 2: ...6 6 MEASURING PROCEDURE 7 6 1 Using the instrument in a Single Phase plant 7 6 2 Using the instrument in a Three Phase plant 9 7 LED MESSAGES DESCRIPTION 11 8 CONNECTION OF INSTRUMENT TO PC 11 9 MAIN...

Page 3: ...s Danger high voltage risk of electrical shocks De energize the plant under test before connecting the instrument Double insulated meter AC voltage and current 1 1 PRELIMINARY INSTRUCTIONS This instru...

Page 4: ...the source of low voltage installations Examples are electricity meters and measurements on primary overcurrent protection devices and ripple control units Measurement category III is for measurement...

Page 5: ...ingle phase or three phase plant Where not expressly indicated the characteristics are common for both models The meter can monitoring a plant for a long time thanks to a sophisticated memory managing...

Page 6: ...ph 10 1 2 For battery fitting operation procedure please see paragraph 9 2 WARNING The meter after fitted batteries is always continuously ON also if STATUS and ALARM LED are OFF Pressing of START STO...

Page 7: ...rnal clock Set instrument date and time Check battery status How to operate 1 Connect the instrument to PC COM using included serial cable 2 Run DATALINK software 3 Choose the correct COM port with th...

Page 8: ...n the middle of the head 5 Re energize the plant under test 6 How to start a Recording If no recording was performed or if the recording data was already downloaded to a PC pressing and keeping the ST...

Page 9: ...ion is possible During Recording operations RS 232 serial communications to PC is not possible 8 Stop a Recording To stop a Recording pressing START STOP key and keep it pressed for 3 seconds The STAT...

Page 10: ...he middle of the head 5 Re energize the plant under test 6 How to start a Recording If no recording was performed or if the recording data was already downloaded to a PC pressing and keeping the START...

Page 11: ...ion is possible During Recording operations RS 232 serial communications to PC is not possible 8 Stop a Recording To stop a Recording pressing START STOP key and keep it pressed for 3 seconds The STAT...

Page 12: ...NNECTION OF INSTRUMENT TO PC Connection of the instrument to a PC is made with a serial cable supplied with the instrument To download data to the PC after installation of DATALINK software keep to th...

Page 13: ...ING Only experts and trained technicians should perform this operation Remove the flexible head from the conductor under test before replacing the batteries 1 Stop the recording if necessary remove th...

Page 14: ...ht 2000m Overvoltage category CAT III 1000V to ground CAT IV 600V to ground 10 1 2 General data Mechanical characteristics Size 120 L x 80 W x43 D mm Max diameter cable clamped 174mm Head length 600mm...

Page 15: ...Damages caused by incorrect shipping procedures Damages caused by repair service trials of unauthorized people Modifications to the equipment without explicit authorization of our Technical Dept Adapt...

Reviews: