Horisont Safety Systems AB • Ängsgatan 11 • SE 828 32 Edsbyn
Mainphone: +46 (0) 271-212 75
www.horisontsafety.se
Horisont Stairway
Assembly
Mounting the beam
For selection of beam sections and number of steps, refer to fig. 5, and “Table
for supports and beams” on page 9.
1. Select a surface that is as level as possible.
2. Lay the collapsed beam sections with the cross braces downwards.
3. Fold out the beam section side beams and lock them with the hinged frames.
Pic 28. Beam sections with the cross braces downwards
4. Lay out the sections after one another and turn them over so that the cross
braces form the top surface (an outer section Y12 and an additional one or
two intermediate sections M6 followed by an outer section).
5. Take the supplied bolts.
6. Bolt the sections to each other. Four bolts at the bottom and at least two
bolts at the top on each side. Tighten all bolts equally.
Pic 29. Beam Y12+M6+Y12, assembly