- 34 -
4.2.16 Display notifications
Display notification Meaning
Required action
17.44 V
batt low 1
Undervoltage warning,
Battery empty (batt low 1)
Change / charge battery
17.02 V
BATT LOW 2
Battery empty (batt low 2)
Tool is not working anymore
Change / charge battery
TEMP FET
STOP
Excess temperature „FET“
Let tool and battery cool down
FAIL MOTOR
STOP
Hardware error
(Defect on motor,
Sensor, etc.)
Tool must be serviced
1 9 3 2 0 0 1 9
S e r v i c e C
The tool indicates that the
service interval for the clamp
-
ing area cleaning has been
reached.
Clean clamping jaws
1 9 3 2 0 0 1 9
S e r v i c e B
Maintenance service counter Tool must be serviced
1 9 3 2 0 0 1 9
S e r v i c e A
Complete overhaul service
counter
Tool must be serviced
NOTE
In cases of serious faults corresponding notifications will appear in the
display. The tool must be sent to the manufacturer.