- 29 -
4.2.10 Set fastener
NOTE
Always place the riveting tool at a right angle (90°) to the work surface to be
riveted. An oblique placement leads to faulty riveting. Use only appropriate
mouthpieces for the rivet. An incorrect mouthpiece can lead to damages in
the clamping jaws as well as the mouthpiece. You can find the size of the bore
and the clamping area in the rivet manufacturer’s information.
1. Place blind rivet in mouthpiece.
2. Guide the blind rivet into the hole provided.
3. Press the blind rivet against the component in order to activate the pressure trigger
(chapter 4.2.11 on page 30).
4. Start setting process by pressing the start button, hold start button down.
5. The tool will recognise the break (chapter 4.2.12 on page 31) and automatically returns
to the starting position.
6. Release start button.
7. Let the broken rivet slide into the riveting mandrel containers by tipping the riveting tool.
1
3
2
5