HRW EKey EKRXGSM Quick Start Manual Download Page 7

                    

 

                 

HRW Limited   

       

 HRW Data EKRXGSM 071105    

          

Subject to change without notice   

          Page 7/9 

 

 

Instructions (cont…)

 

 

To set the alarm notification SMS message 

 

Send an SMS message to the EKRXGSM in the following format: 

password:V(text message

 

 

text message 

is any sort of meaningful text message that describes to the recipient that an alarm or 

other condition has been detected by the EKRXGSM’s alarm input circuit. If a null message (ie one 
whithout any characters is set), the EKRXGSM will not send an alarm activated SMS 

 
Eg: Sending the SMS “Password:V(Gate forced alarm)” will cause the EKRXGSM to send the SMS “Gate 
forced alarm” to selected recipients when the EKRXGSM alarm input has been triggered. 
 
Eg: Sending the SMS “Password:V()” will prevent the EKRXGSM from sending an alarm activated message 
when the EKRXGSM alarm input has been triggered. 
 
To set the alarm restored notification SMS message 
 
Send an SMS message to the EKRXGSM in the following format: 

password:U(text message

 

 

text message 

is any sort of meaningful text message that describes to the recipient that an alarm or 

other condition has been detected by the EKRXGSM’s alarm input circuit as returning to a non alarm 
state. 

 
Eg: Sending the SMS “Password:U(Gate forced alarm reset)” will cause the EKRXGSM to send the SMS 
“Gate forced alarm reset” to selected recipients when the EKRXGSM alarm input has been reset. 
 
Eg: Sending the SMS “Password:U()” will prevent the EKRXGSM from sending an alarm reset message when 
the EKRXGSM alarm input has been reset. 
 
Sending multiple commands in one SMS 
 
Multiple commands can be sent in one SMS by using the following format: 

password:command1:command2:….commandx 

etc 

 

 

password 

is the 5…8 character case sensitive alphanumeric master password 

 

command1 

etc are any of the above mentioned configuration commands 

 
Eg: Sending the SMS “Password:D(ALL):E(ALL):A(00001EA5,0000)

:I

(0892481646,secret,1,1,1,1)” will 

 

 

Delete all E-Keys and phone numbers 

 

Add an E-Key with a serial number of 00001EA5 (derived from the S/N:N00001EA5 printed on the E-
Key label) 

 

Add the landline phone number (08) 92481646 with a user password of “secret” 

 

The number and SMS password are valid for use, grouped into group 1 

 

The EKRXGSM will call the phone back for 5 seconds after receiving a successful activation from the 
caller 

 

The EKRXGSM will also send alarm and restore SMS messages if it’s alarm input circuit has been 
activated and non zero alarm messages have been programmed 

 

The default master password of “Password” was used 

 
The number of contiguous commands sent is only limited to the total number of characters used in any one 
SMS. Once the limit of 160 characters is used, the message should be trimmed to the last whole command. 

Summary of Contents for EKey EKRXGSM

Page 1: ...mber restriction E Key addition or deletion etc can be remotely changed via password protected SMS from any mobile phone or by a PC using simple software combined with a GSM modem Applications Garage doors automatic gates Remote arming and disarming of security alarms Remote area control Personal emergency or duress alarms Features Can be used to replace any existing remote control system Free act...

Page 2: ... the telephone is recognised by the EKRXGSM it will command the connected E Key receiver to trigger the equivalent output as would occur if a valid E Key button were pressed Since the call was never answered there will be no call costs associated with the transaction To trigger the E Key receiver by SMS from a recognized mobile telephone Send an SMS message to the EKRXGSM in the following format B...

Page 3: ...SMS Password D ALL will delete all E Keys in the E Key receiver using the default master password of Password To add a new phone number Send an SMS message to the EKRXGSM in the following format password I nnnnnnnn smspass z v e s password is the 5 8 character case sensitive alphanumeric master password nnnnnnnn is the 8 digit mobile number or 8 digit landline number min 8 digits max 15 digits if ...

Page 4: ...ered where 1 activates the feature and 0 disables it Eg Sending the SMS Password I 0892481646 nosecret 6 1 0 0 will modify the status of the landline phone number 08 92481646 with a user password of nosecret The number and SMS password are valid for use grouped into group 6 with echo and alarm messaging disabled Eg Sending the SMS Password I 0411115856 secret 1 0 0 1 will modify the status of the ...

Page 5: ...assword Eg Sending the SMS Password C 07 07 01 14 30 00 will set the clock to 2 30pm on 1st July 2007 with a time zone offset of GMT 0 hours using the default master password of Password To change the master password Send an SMS message to the EKRXGSM in the following format password W newpassword password is the 5 8 character case sensitive alphanumeric master password newpassword is the new 5 8 ...

Page 6: ...he EKRX42S instructions for further options Eg Sending the SMS Password L 10000 to an EKRXGSM connected to a EKRX44S receiver will act as if the FF link are fitted This will enable E Key buttons 1 4 to activate relays 1 4 respectively in four channel mode with flip flop enabled See the EKRX44S instructions for further options To set the default button activation when receiving an incoming call Sen...

Page 7: ...e EKRXGSM to send the SMS Gate forced alarm reset to selected recipients when the EKRXGSM alarm input has been reset Eg Sending the SMS Password U will prevent the EKRXGSM from sending an alarm reset message when the EKRXGSM alarm input has been reset Sending multiple commands in one SMS Multiple commands can be sent in one SMS by using the following format password command1 command2 commandx etc ...

Page 8: ...fixed number of 3212345 would be stored as 6793212345 Presuming that all the above phone numbers were programmed into the EKRXGSM database the number of digits for phone number comparison Function O should be set as follows depending on which country the EKRXGSM is located Located in Hong Kong the number of digits compared should be 8 In Australia the number of digits compared should be 9 In New Z...

Page 9: ...f 1 Amp Power is supplied via a 2 1mm DC connector with the centre pin being positive Technical Data Power supply Max number of valid E Keys Max number of valid phone numbers Telecommunications Frequency Compatible E Key Receivers Dimensions mm 7 16Vdc 1A peak 340 340 Quad band GSM EKRX42 S EKRX44 S 80 x 72 x 30 Ordering EKRXGSM Four channel RF key with code hopping security in keyfob style packag...