HQUA
Debugging
Connect the power supply firstly, and check the indicator light to see if UV water sterilizer is working
well.Wait for 10-15 minutes to re-use faculets.
3.2 Clean&Replace the Quartz Sleeve
The coating on the quartz sleeve will slowly form due to the minerals in the water. This coating must
be removed because it reduces the amount of UV light reaching the water, thereby reducing
disinfection performance. If the sleeve can not be cleaned, it must be replaced.
Prerequisites:
•
Close the water supply of your system and drains all lines. Make sure the water in the chamber lower
than the quartz sleeve.
• Depressurize the unit. Place a small pail under the unit to catch any spills.
• Remove the UV lamp; Refer to
Section 3.1