7
Error Code List
Code on LCD screen
Corresponding error
E0
No error
E1
battery over-discharging
E2
battery overvoltage
E4
Load short circuit
E5
Overload
E6
Controller inner temperature over heat
Common Problems and Solutions
Symptoms
Causes and Solutions
LCD screen does not light up.
Check whether the battery is correctly connected.
Incomplete display or no renewal on LCD screen
Check whether the ambient temperature is too low and whether
the display recovers when the temperature rises.
No charging with sunlight present
Check whether the solar panel is correctly connected, and
contact is good and reliable.
Check whether the solar panel voltage falls below the battery
voltage.
The battery icon flashes quickly, and there is no output.
System overvoltage. Check whether the battery voltage is too
high.
The battery icon flashes slowly, and there is no output.
The battery is over-discharged, and will recover after recharged
adequately.
The load icon flashes quickly, and there is no output.
The load's power exceeds the rated value or the load is short-
circuited. After the problem is solved, long press the key or wait
until it recovers automatically.
Other symptoms
Check whether wiring is sound and reliable, and system voltage
is correctly recognized.
Solar Panel Technical Data Sheet
Standard Testing Conditions (STC): 1000W/m
2
, T = 25°C, AM = 1.5
Max Power at STC
100 W
Open circuit voltage (Voc)
21.6 V
Optimum operating voltage (Vmp)
18.0 V
Optimum operating current (Imp)
2x2.78 A
Short circuit current (Isc)
2x3.08 A
Cell Type
Monocrystalline
Number of Cells
36 per panel (3 x 12 arrangement)
Max system voltage
600VDC (UL)
Max series fuse rating
15 A
Fire rating
Class C
Weight
27.05 lbs.
Dimensions Unfolded (l x h x w)
39.8 x 27.2 x 1.5 in
Dimensions Folded (l x h x w)
19.9 x 27.2 x 2.8 in