Tips on Using Snow Machines 

 

During operation, the tank of the snow machine must be filled at all times. 

Running the snow machine without 

liquid will destroy the pump almost instantly!

 Please make sure to fill the tank and to place the end of the tube at 

the bottom of the tank before plugging the snow machine into the mains.  

 

Prevent the tube from clogging by cleaning your snow machine after each use. Place the end of the tube into a cup 

and run 25cl of lukewarm water through the tube. 

 

4. Installation 

 

a) Fuse 

 

 

Only fit or replace a fuse when the device is unplugged from the mains. 

 

Replace a blown fuse with a fuse of the same type and rating (see “

Technical Specifications

”): 

1.  Remove the fuse holder on the backside under the power input with an appropriate screwdriver. 

2.  Remove the old fuse and install a new one. 
3.  Replace the fuse holder and replace the fuse holder. 

 

b)  Mounting the Device 

 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms. 

 

The carrying construction must be able to support 10 times the weight of the device for 1 hour without deforming. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

 

Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician 

check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating workload limits, determining the installation 

material to be used… Have the material and the device itself checked regularly. Do not attempt to install the 
device yourself if you lack these qualifications as improper installation may result in injuries. 

 

Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws. 

 

Make sure there is no flammable material within a 0.5m radius of the device. 

 

Have a qualified electrician carry out the electric connection. 

 

Connect the device to the mains with the power plug. Do not connect it to a dimming pack. 

 

The installation has to be approved by an expert before the device is taken into service. 

 

5. Use 

 

a. DMX-512 Connections 

 
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side to the male 3-

pin XLR input of the 

VDP1000SWN

. Multiple 

VDP1000SWN

s can be linked through serial linking. The linking cable 

should be a two-core screened cable with XLR input and output connectors. Please refer to the diagram. 

 

b.  DMX-512 Chain with termination 

 

A DMX terminator is recommended for installations where the DMX cable has to run a 

long distance or is in an electrically noisy environment (e.g. discos). The terminator 
prevents corruption of the digital control signal by electrical noise. The DMX terminator is 

simply an XLR plug with a 120

 resistor between pins 2 and 3, which is then plugged into 

the XLR output socket of the last device in the chain. 

Please see illustrations. 

 

Summary of Contents for VDP1000SWN

Page 1: ...DMX GESTUURDE SNEEUWMACHINE 1000W MACHINE EFFET NEIGE CONTR L PAR DMX DE 1000W M QUINA DE NIEVE CONTROLADA POR DMX 1000W SCHNEEMASCHINE 1000W DMX GESTEUERT USER MANUAL GEBRUIKERSHANDLEIDING NOTICE D E...

Page 2: ...ge does not exceed the voltage stated in the specifications of this manual Do not crimp the power cord and protect it against damage Have an authorised dealer replace it if necessary Disconnect the de...

Page 3: ...ce in a location with few passers by that is inaccessible to unauthorised persons Overhead mounting requires extensive experience calculating workload limits determining the installation material to b...

Page 4: ...machine Turn the power supply switch of the machine to ON and then the RED indication light on the controller will be on POWER 2 Turn the on off switch 4 to I and the green light will be on The snow...

Page 5: ...chteraan de handleiding De voedingskabel mag niet omgeplooid of beschadigd zijn Laat uw dealer zo nodig een nieuwe kabel plaatsen Trek de stekker uit het stopcontact trek niet aan de kabel voordat u h...

Page 6: ...eer dit toestel op een plaats waar niemand langs moet lopen kan neerzitten of het toestel kan aanraken Een degelijke praktijkervaring is vereist voor de plaatsing van dit toestel U moet de maximumbela...

Page 7: ...toestel en koppel aan het lichtnet Schakel het toestel in met behulp van de voedingsknop ON De rode LED op de controller licht op POWER 2 Plaats de on off schakelaar 4 op I de groene LED licht op Het...

Page 8: ...s sp cifications la fin de cette notice Le c ble d alimentation ne peut pas tre repliss ou endommag Demandez votre revendeur de renouveler le c ble d alimentation si n cessaire D branchez l appareil s...

Page 9: ...r ou s asseoir et o personne ne peut le toucher L installation de cet appareil exige une solide exp rience pratique le calcul de la charge max de la construction les mat riaux d installation requis et...

Page 10: ...de l appareil Allumez l appareil en pla ant l interrupteur d alimentation sur ON La LED rouge sur le contr leur s allume POWER 2 Placez l interrupteur on off 4 sur I La LED verte s allume L appareil p...

Page 11: ...erficie afilada Si es necesario pida a su distribuidor reemplazar el cable de alimentaci n Desconecte siempre el aparato si no va a usarlo durante un largo per odo de tiempo o antes de limpiarlo Tire...

Page 12: ...alcance de personas no autorizadas y en un lugar con poca gente La instalaci n de este aparato exige una s lida experiencia pr ctica debe poder calcular la carga m x del soporte debe conocer los mate...

Page 13: ...ucciones Introduzca el conector del cable de alimentaci n en la base de la parte trasera del aparato Active el aparato al colocar el interruptor en ON El LED rojo del controlador se ilumina POWER 2 Po...

Page 14: ...oder durch scharfe Kanten besch digt werden kann Bei Besch digungen soll eine Fachkraft das Kabel ersetzen Trennen Sie das Ger t bei Nichtbenutzung und vor jeder Reinigung vom Netz Fassen Sie dazu den...

Page 15: ...nbetriebnahme von einem Fachmann pr fen Montieren Sie das Ger t an einem Ort an dem es wenig Vor bergehende gibt und der unzug nglich ist f r Unbefugte Oberirdische Montage erfordert erhebliche Sachke...

Page 16: ...e an der R ckseite des Ger tes Drehen Sie den EIN AUS Schalter des Ger tes auf ON die ROTE Anzeigeleuchte wird aufleuchten POWER 2 Drehen Sie den EIN AUS Schalter auf 4 und die gr ne Anzeigeleuchte wi...

Reviews: