GS ( k pL pH cn fn n (cn = 49, fn = 67)
[Name]
QR Code: Set the size of module
[Format]
ASCII
GS
(
k
pL pH cn fn n
Hex
1D
28 6B
pL pH cn fn n
Decimal
29
40 107
pL pH cn fn n
[Range]
(pL + pH × 256) = 3 (pL = 3, pH = 0)
cn = 49
fn = 67
1 ≤ n ≤ 8
[Dscription]
• Sets the size of the module for QR Code to n dots.
[Default]
[Default]
GS ( k pL pH cn fn n (cn = 49, fn = 69)
[Name]
QR Code: Select the error correction level
[Format]
ASCII
GS
(
k
pL pH cn fn n
Hex
1D
28
6B
pL pH cn fn n
Decimal
29
40
107
pL pH cn fn n
[Range]
(pL + pH × 256) = 3 (pL = 3, pH = 0)
cn = 49
fn = 69
48 ≤ n ≤ 51
[Dscription]
• Selects the error correction level for QR Code
n
Function
Reference: Approx. figure of recovery
48
Select error correction level L
7%
49
Select error correction level
M
15%
50
Select error correction level Q
25%
51
Select error correction level H
30%
GS ( k pL pH cn fn m d1…dk (cn = 49, fn = 80)
[Name]
QR Code: Store the data in the symbol storage area
[Format]
ASCII
GS
(
k
pL pH cn fn m d1…dk
Hex
1D
28 6B
pL pH cn fn m d1…dk
Decimal
29
40 107
pL pH cn fn m d1…dk
[Range]
4 ≤ (pL + pH × 256) <1021 (0 ≤ pL ≤ 255, 0 ≤ pH< 4)
cn = 49
fn = 80
m = 48
0 ≤ d ≤ 255
k = (pL + pH × 256) – 3
[Dscription]
•Stores the QR Code symbol data (d1...dk) into the symbol storage area