7.4 Cash Drawer Interface Signal
1) Electrical Characteristics
Driving voltage
:
DC 24 V
Driving current
:
maximum 0.8 A ( In 510 ms)
Drawer check signal
:
“L” = 0
~
0.5 V
“H” = 3
~
5 V
2) Cash Drawer Interface Sing RJ-11 Connector
Figure 7.4.1
Interface signal definition
Pin No.
Signal
Function
1
FG
Frame Ground
2
DRAWER 1
Drawer kick-out drive signal 1
3
DRSW
Drawer open/close signal
4
VDR
Drawer driving source
5
DRAWER 2
Drawer kick-out drive signal 2
6
GND
GND
Note
:
Strictly prohibit to hot plug the plug.
When arranging the line of communication, you have to avoid paralleling with the strong current.
You have to use the shielded communication line.