Warranty
HPM Cat XLP912WEWE & XLP913WEWE are warranted
as here and after appears, against faulty material and/
or workmanship for a period of one year from the day of
purchase. The obligation of the manufacturer under this
warranty is limited to servicing and replacing defective
parts when the unit is returned to the authorised place
of purchase. To obtain warranty repair, the purchase
receipt should be returned with the product. This warranty
becomes void on any unit which has been tampered with
or damaged by accident, short circuited, loaded beyond
rating or damaged otherwise by improper operation. The
warranty is also conditional on the unit being installed
by a licensed electrical contractor. All other warranties,
whether expressed or implied, and whether arising by
operation of law or otherwise are hereby excluded.
23956A
The 2-wire XLP913WEWE dims the load up and
down over a few seconds when switching on and
off. It does this in either leading or trailing edge
mode, depending on the type of load connected.
The unit can be set to automatically detect the load
type, or manually set to either leading or trailing
edge.
Automatic load detection (factory default setting)
The unit will detect the load and automatically
select leading or trailing edge. Press and hold
middle and right buttons for 10 seconds.
Trailing edge mode
Use for incandescent or electronic transformer loads.
Press and hold left and middle buttons for 10 seconds.
Cat No
XLP912WEWE XLP913WEWE
Supply voltage
230-240V a.c. 230-240V a.c.
2 or 3 wire
3 wire
2 wire
Minimum load
0W
40W
Maximum load
See Load Compatibility
Terminal capacity 2 x 1.5mm
²
or 1 x 2.5mm
²
IP rating
IP41
Storage
temperature
0
°
C to +35
°
C
Operating
temperature
0
°
C to +35
°
C
Resistant to the
following agents
Hexane, methylated spirits, soapy
water, diluted ammonia, diluted
pure bleach (10%), glass cleaning
substance, pre-impregnated wipes
Not resistant
to the following
agents
Acetone, tar remover,
trichloroethylene
Leading edge mode
Use for incandescent or ferromagnetic transformer
loads. Press and hold left and right buttons for 10
seconds.
5
Dimming Mode (XLP913WEWE Only)
Warning:
These products must only be connected to
the mains supply by a qualified electrician.
Technical Characteristics