Warranty

HPM Cat XLP912WEWE & XLP913WEWE are warranted 
as here and after appears, against faulty material and/
or workmanship for a period of one year from the day of 
purchase. The obligation of the manufacturer under this 
warranty is limited to servicing and replacing defective 
parts when the unit is returned to the authorised place 
of purchase. To obtain warranty repair, the purchase 
receipt should be returned with the product. This warranty 
becomes void on any unit which has been tampered with 
or damaged by accident, short circuited, loaded beyond 
rating or damaged otherwise by improper operation. The 
warranty is also conditional on the unit being installed 
by a licensed electrical contractor. All other warranties, 
whether expressed or implied, and whether arising by 
operation of law or otherwise are hereby excluded.

23956A

The 2-wire XLP913WEWE dims the load up and 

down over a few seconds when switching on and 

off. It does this in either leading or trailing edge 

mode, depending on the type of load connected. 

The unit can be set to automatically detect the load 

type, or manually set to either leading or trailing 

edge.

Automatic load detection (factory default setting)

The unit will detect the load and automatically 

select leading or trailing edge. Press and hold 

middle and right buttons for 10 seconds.

Trailing edge mode

Use for incandescent or electronic transformer loads. 

Press and hold left and middle buttons for 10 seconds.

Cat No

XLP912WEWE XLP913WEWE

Supply voltage

230-240V a.c. 230-240V a.c.

2 or 3 wire

3 wire

2 wire

Minimum load

0W

40W

Maximum load

See Load Compatibility

Terminal capacity 2 x 1.5mm

²

 or 1 x 2.5mm

²

IP rating

IP41

Storage 

temperature

0

°

C to +35

°

C

Operating 

temperature

0

°

C to +35

°

C

Resistant to the 

following agents

Hexane, methylated spirits, soapy 

water, diluted ammonia, diluted 

pure bleach (10%), glass cleaning 

substance, pre-impregnated wipes

Not resistant 

to the following 

agents

Acetone, tar remover, 

trichloroethylene

Leading edge mode

Use for incandescent or ferromagnetic transformer 

loads. Press and hold left and right buttons for 10 

seconds.

5

Dimming Mode (XLP913WEWE Only)

Warning: 

These products must only be connected to 

the mains supply by a qualified electrician.

Technical Characteristics