Document No.: G304eS/AFMSupp, R01
Date of Issue: 11/17
2-10
H
P
H
Ltd.
WARNING
If pilot do not stop motor in case of warning
Critical Voltage, Stop
FES motor!
, red warning message appears, counting down 30
seconds. After 30 second FCU will stop motor automatically, in order
to protect batteries from over discharge.
During 30 seconds of count-down pilot can decide to press throttle
knob to override automatic motor stop. Message will disappear and
motor will continue to run. Each override action is saved to the
memory of FCU instrument.
See FCU INSTRUMEN manual section 8.3.1 for further information.
2.14.6 List of all temperature warnings
Condition
Level
FCU warning
Required action
Battery pack warning messages, based on temperature
measurements of each pack
Battery pack
temperature is below
5°C
yellow
Battery Temp.
Low < 5°C,
Consider that full
power cannot be
maintain for a
longer time
Temperature
difference between
each Battery pack is
more than 3°C
yellow
Battery diff.
> 3°C, Reduce
power!
Reduce power to
keep continuous
operation
Temperature
difference between
each Battery pack is
more than 6°C
Red
Battery diff.
> 6°C, Stop
FES motor!
Stop FES motor
Battery pack high
temperature, more
than 45°C
yellow
Battery High
> 45°C, Reduce
power!
Reduce power to
keep continuous
operation
Battery pack extremely
high temperature,
more than 55°C
Red
Batt. Ext. High
> 55°C, Stop
FES motor!
Stop FES motor
Battery pack
temperature is critical,
more than 75°C
Red
Batt. Critical
> 75°C, Land
immediately!
Stop FES motor