Fan population rules
The following table lists the valid fan configurations.
Configuration
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6
Fan 7
Fan 8
Single processor –
Non-Redundant
Fan
blank
Fan
Fan
Fan
Empty
Empty
Empty
Empty
Dual processor –
Non-Redundant
Fan
Fan
Fan
Fan
Empty
Empty
Empty
Empty
Single processor -
Redundant
Fan
blank
Fan
Fan
Fan
Empty
Fan
Fan
Fan
Dual processor -
Redundant
Fan
Fan
Fan
Fan
Fan
Fan
Fan
Fan
For a single-processor redundant configuration, six fans and one blank is required in specific fan bays for
redundancy. A fan failure causes a loss of redundancy. A second fan failure causes an orderly shutdown of
the server.
Installing more than the required number of fans in a single-processor configuration is not a supported
configuration.
For a dual-processor redundant configuration, all fans are required for redundancy. A fan failure causes a loss
of redundancy. A second fan failure causes an orderly shutdown of the server.
The server supports variable fan speeds. The fans operate at minimum speed until a temperature change
requires a fan speed increase to cool the server. The server shuts down during the following temperature-
related scenarios:
1.
At POST and in the OS, iLO performs an orderly shutdown if a cautionary temperature level is detected. If
the server hardware detects a critical temperature level before an orderly shutdown occurs, the server
performs an immediate shutdown.
2.
When the Thermal Shutdown feature is disabled in RBSU, iLO does not perform an orderly shutdown
when a cautionary temperature level is detected. Disabling this feature does not disable the server
hardware from performing an immediate shutdown when a critical temperature level is detected.
100
Component identification
Summary of Contents for ProLiant ML350
Page 12: ...12 Customer self repair...
Page 13: ...Customer self repair 13...
Page 14: ...14 Customer self repair...
Page 15: ...Customer self repair 15...
Page 25: ...Illustrated parts catalog 25...
Page 64: ...SFF configuration Two SAS Expanders 64 Removal and replacement procedures...
Page 91: ...Rack orientation 24 LFF drives Tower orientation Component identification 91...
Page 106: ...Storage controller installed in slot 6 to 9 106 Cabling...
Page 115: ...SFF configuration Two SAS Expanders Cabling 115...