2
Par action : FWD
Flags
Link fault : Not occurred
Dying gasp : Not occurred
Critical event : Not occurred
Local evaluating : COMPLETE
Remote evaluating : COMPLETE
Packets statistics
Packet type Sent Received
-----------------------------------------------------------------
OAMPDU 100 80
OAMInformation 64 60
OAMEventNotification 36 20
OAMUniqueEventNotification 36 10
OAMDuplicateEventNotification 0 10
Table 1 Command output
Field Description
Ten-GigabitEthernet1/0/1
Information on Ten-GigabitEthernet 1/0/1.
Enable status
Ethernet OAM state (enabled or disabled).
Loopback status
Ethernet OAM loopback state:
•
No
loopback.
•
Remote
loopback.
•
Local
loopback.
Link status
Link state (UP or DOWN).
OAM mode
Local Ethernet OAM mode:
•
Active—
The port is operating in active Ethernet OAM mode.
•
Passive—
The port is operating in passive Ethernet OAM mode.
PDU
The way in which the local end processes Ethernet OAMPDUs:
•
RX_INFO—
The port only receives Information OAMPDUs and does
not send any Ethernet OAMPDUs.
•
LF_INFO—
The port only sends the Information OAMPDUs without
Information TLV triplets and with their link error flag bits being set.
•
INFO—
The port sends and receives only Information OAMPDUs.
•
ANY—
The port sends and receives Ethernet OAMPDUs of any
type.
Mux action
Operating mode of the local transmitter:
•
FWD—
The port can send any packets.
•
DISCARD—
The port only sends Ethernet OAMPDUs.
Par action
Operating mode of the local receiver:
•
FWD—
The port can receive any packets.
•
DISCARD—
The port only receives Ethernet OAMPDUs.
Flags
Local flags inserted in the local flag fields of the Ethernet OAMPDUs sent.
Link fault
Indicates whether an Ethernet OAM link error is present.
Dying gasp
Indicates whether a fatal error is present.
Critical event
Indicates whether a critical error is present.