Installing the chassis
Installation overview
To set up and install the chassis:
1.
Unpack the system (
Unpacking the system
on page 20).
2.
Determine the chassis rack spacing (
Determining the chassis rack spacing
on page 20).
3.
Install the rack rails (
Installing the rack rails
on page 20).
4.
Install the chassis into the rack (
Installing the chassis in the rack
on page 24).
5.
Install the system components (
Installing the system components
on page 28).
6.
Connect power to the chassis (
Cabling the chassis
on page 41).
Unpacking the system
Unpack the following hardware and prepare for installation:
• HPE Apollo k6000 Chassis
• HPE Apollo k6000 Chassis Rack Rail Kit
• Chassis components and cabling
The following documents also ship with the HPE Apollo k6000 Chassis:
• Start Here for Important Setup Information
• Safety, Compliance, and Warranty Information
Determining the chassis rack spacing
The HPE 1.2 m standard rack supports installation of up to three chassis.
For more information on installing the chassis into the rack, see the
HPE Apollo k6000 Chassis Rail Kit for
HPE and Third Party Racks Installation Instructions
.
Installing the rack rails
WARNING:
To reduce the risk of personal injury or damage to the equipment, be sure that:
• The leveling jacks are extended to the floor.
• The full weight of the rack rests on the leveling jacks.
• The stabilizing feet are attached to the rack if it is a single-rack installation.
• The racks are coupled together in multiple-rack installations.
• Only one component is extended at a time. A rack may become unstable if more than one
component is extended for any reason.
20
Installing the chassis