0
3. Switch the machine on. From the main screen, click
“TOOLS” (Fig. 3)
then click
“SPECIAL FUNCTION”
then click
“UPDATE FROM CARD”
When prompted, click
“CONFIRM”
.
4. The screen will turn white for approximately 7 minutes, then will turn black for a shorter period, and then beep.
The beep indicates that the AutoCal program is loaded.
CAUTION: Do not turn the machine
off during the loading of the
Auto-Calibrate program.
Once the Auto-Calibration program
is properly installed, the machine
can be switched off as needed.
5. While the Auto-Calibrate Program is loading, remove the cutter and install the Calibration Disk. The screen will
now indicate
”AUTO CALIBRATE” (Fig. 4).
Auto-Calibrate
4$)-"(&45"/%"3%
-"45%4%
13&4&5
13&4&5
13&4&5
%4%
$@KHAQ@SD
5NNKR 3DRDS
Click the
“CALIBRATE”
button. The next menu will read
“**Mount Shoulder
Gauge Tool**”
.
Place the Calibration Key in Jaw A and align with the shoulder
gauge. After aligning Calibration Key, lower the shoulder gauge to the rest
position
(Fig. 5)
, and press
“Continue”.
6. The carriage will now slowly move in toward the Calibration Disk. The disk will make contact at a number of
points on the Calibration Key. This phase of the program takes about 60 seconds. When this phase is com-
pleted the Tiger SHARK™ will stop and beep 3 times while changing screens.
8. The Tiger SHARK™ will continue to self-calibrate by repeating the touch off routines it did for the shoulder
gauge. This phase will take about 30 seconds. After it finishes the machine will beep 4 times to tell you it has
completed the self-calibration. When prompted, click
“Confirm”
The screen will change to the main menu.
9. Remove the Calibration Key and Calibration Disk. Install a No. CW-14MC cutter and a standard shoulder
gauge key blank. (eg. Schlage SC1).
10. On the menu, click DSD, then type in “Schlage” or DSD number 60. Follow the instructions on screen, and cut
5-depths in all positions.
If a Schlage key blank is not available, select another standard shoulder gauge key
blank, and use the appropriate DSD number and cutter.
11. Use a key micrometer (such as the HPC Ultimate Micrometer, No. SKM-2D) to measure the depths of each cut.
Compare the depths obtained to the depths listed in HPC CodeSource® program, or other reliable source. All
cuts should be within .002” (.05mm) of the manufacturer’s specification (260-inch for a Schlage 5-depth). In most
cases no further adjustments will be needed.
Note: do not cut a key using a DSD where you have made DSD-specific adjustments, as these adjust-
ments will not be a true reading of the machine’s current state of calibration.
7.
The screen will read
“*Set tool for tip adjustment*”
. Remove the Calibration Key, turn it around, and gauge it
with the tip gauge
(Fig. 6)
. Press the
“DO TIP”
button.
Fig. 5
Fig. 6
38
Summary of Contents for Tiger SHARK
Page 2: ......
Page 12: ...10...
Page 16: ...14...
Page 17: ...15 Tiger SHARK 3 1 Loading Key Blanks 3 2 Gauging Methods 3 3 4 Way jaws LOADING GAUGING KEYS...
Page 20: ...18...
Page 21: ...19 Tiger SHARK 4 1 Cutting by DSD 4 2 Cutting by Code 4 3 Cutting Specialty Keys KEY CUTTING...
Page 30: ...28...
Page 50: ...48...
Page 63: ......
Page 64: ......
Page 65: ......