2)
If using remote control, turn “off” electrical power or gas to fire pit.
3)
Once fire pit has cooled completely, use appropriate cover to protect fire pit.
Fire Pit Maintenance:
1)
Keep fire pit covered at all times when not in use.
2)
Keep any debris out of fire pit- clean as needed.
3)
Flame Sensor Cleaning of Soot:
Remove lava rock, glass and blow out box. Clean flame sensor of
any soot. Be careful not to damage ceramic insulators or hot surface ignition element. Place lava rock
or glass back as explained on Pg. 5.
Fig. 1
Here is some additional helpful information to keep in mind:
Fire Pits Dimensions:
Are approximately
12”
from the bottom of the valve box to the lip of the burner pan. HPC
can provide drawings if so desired.
Installation Collars
are available that can be mortared into enclosure and allow for fire pit to be
easily removed for maintenance. Installation Collars measure as follows:
Fire
Pit
Size
Collar
I.D. Collar
O.D.
19”
20”
26”
25”
26”
32”
31”
32”
38”
37”
38”
44”
Gas Line Construction:
Main fire pit gas supply lines that transition from large ID to smaller ID (i.e. 1” ID supply
line to ½” ID) line will result in more noticeable noise when burner is in operation. This is particularly noticeable
when transition is installed inside fire pit structure. Installer should also minimize long runs of corrugated supply
lines to fire pit. Utilizing smooth bore gas supply (hard pipe) lines, shorter flex lines and avoid steep ID transitions
near interior of fire pit will reduce but not eliminate operational noise. Some noise is normal in burner operation.
You can visit our website at
www.hearthproductscontrols.com
line of indoor and outdoor products. We design and build “CUSTOM FIRE PITS”
Limited Warranty
Hearth Products Controls Company (HPC) warranties complete firepits against
manufacturing defects that prevent safe and correct function as follows:
●
Electronics, Gas Valve, & Pilot Assembly: Commercial-6mos; Residential- 1 yr.
●
Stainless Steel Pan, Fire Ring, & Valve Box: Commercial-1yr.; Residential 3yrs.
This commences from the date of original sale / shipment from HPC FOB Dayton, Ohio.
This warranty is for parts and in-house (HPC) labor. The defective product must be
sent back to HPC with a Return Merchandise Authorization (RMA) issued by HPC for
that specific product and any other additional information for the nature of the defect
or warranty claim.
The warranty does not cover items that have been damaged by overheating,
modification, abuse, or improper storage. Also any labor involving installation or
maintenance with the unit is not covered.
This warranty excludes claims for consequential, indirect-collateral expenses
arising from product defects or warranty recovery.
4/2/2009