4.
Configure the EMU:
a.
Connect to the Enclosure Manager software using an
ssh
compatible tool like PuTTY. In
the PuTTY session basic options, enter the EMU IP address (10.0.0.10) and port (22),
and select
SSH
for the connection type (
Figure 9 (page 17)
).
NOTE:
See
“Managing the EMU” (page 131)
for information on using CLI commands.
Figure 9 Connecting to the Enclosure Manager software
b.
After you have connected to the EMU port, set the following attributes:
•
EMU (DNS) name
•
Rack name
•
EMU password (located on the tear-away label on the back of the server blade; see
Figure 10 (page 17)
)
•
IP addressing method
To change the static IP address, type the command
set ipconfig static
at the command line prompt and follow the instructions.
◦
◦
To change the EMU addressing to DHCP, type
set ipconfig dhcp
at the
command line prompt.
Figure 10 Tear-away label location
Example 1 Setting attributes
CustomerEMU-dnsName> set em name CustomerEMU-dnsName
CSP Enclosure Manager name changed to CustomerEMU-dnsName.
CustomerEMU-dnsName> set rack name CustomerRackName
Changed rack name to "CustomerRackName".
Configure the EMU and iLO management processors
17