63
Chapter 6
Troubleshooting
Preventive Maintenance Procedures
Refer to the following table for preventive maintenance procedures used for the hp server tc2120. Be sure to
turn off power to the server when cleaning it.
HP recommends the periodic cleaning of tape heads, capstans, and guides on HP tape drive units and those
products using high-density data cartridges and mini-data cartridges. These maintenance procedures prolong
tape and head life and helps reduce read/write errors due to dust and oxide.
Troubleshooting Checklist
Begin with the procedures in this section as the first step in troubleshooting a problem with the server.
Server Does Not Power On
Follow these steps if the power/activity light does not light green after you press the power-on button.
1. Remove the AC power cord, wait 15 seconds, reconnect the power cord, and try again.
2. Verify all cables and power cords are firmly plugged into the respective receptacles.
3. Select the correct setting on the voltage switch located beside the power connector on the rear panel.
Component
Time Frame
Maintenance Procedure
Keyboard
Regularly
Dust with damp, lint-free cloth.
Monitor screen
Regularly
Use “HP Video Screen Cleaning
Solution” found in 92193M
Master Clean Kit.
Mouse
Regularly
Refer to the mouse’s manual for
mouse maintenance procedures.
Tape drive heads
Monthly
Use “Magnetic Head Cleaning
Solution” found in the 92193M
Master Clean Kit.
Cooling fans and
grilles
6 Months
Check cooling fan operation and
clean the air intake openings on
the chassis by removing any dust,
lint, and other obstructions to
airflow.
CAUTION
Do NOT use petroleum-based cleaners (such as lighter fluid
or cleaners containing benzene, trichlorethylene, ammonia,
dilute ammonia, or acetone. These chemicals could damage
the keyboard’s plastic surfaces).
NOTE
A system hang (Server does not complete boot process) could
be due to an improperly installed heat sink on the processor. If
the heat sink is not properly installed on the processor, the
processor may overheat causing intermittent or unreliable
operation leading to a possible system crash and permanent
damage to the processor