Chapter 3
Installing and Configuring
The IDE Server model uses the IDE-1 for the boot drive and the IDE-2 connector for the IDE CD-ROM. The
Setup Utility (BIOS) can be used to change the boot order of the flexible disk drive and the IDE devices.
Refer to “BIOS Setup Utility” later in this chapter for more information.
IDE Mass Storage Additions
Table 3-1 lists the number and types of mass storage devices that may be added to the IDE model of the HP
Server.
Table 3-1. IDE Model Mass Storage Devices
Interface
Types
Max No.
Devices
Installed Devices and Addresses
FDD
1
Factory installed flexible disk drive (FDD) in shelf 1
IDE-2 2
·
Factory installed CD-ROM drive in shelf 2
·
Optional IDE device (backup tape drive, CD-ROM, or
DVD drive) in shelf 3
·
Optional 3rd IDE hard drive in shelf 4
IDE-1 2
·
Factory installed IDE hard drive in shelf 5
·
Optional 2nd IDE hard drive in shelf 6
SCSI
controller
board
1
·
Optional SCSI backup tape drive in shelf 3 (SCSI
controller board required for SCSI back up tape drive)
SCSI Mass Storage Devices
This section provides the configuration of the SCSI mass storage devices, if you have selected a SCSI version
of the HP Server tc2110. The base SCSI model configuration has at least one SCSI hard drive (shelf 5)
located in the drive cage and connected to the factory installed SCSI controller.
SCSI Controller Configuration
The single channel SCSI controller board provided with the SCSI model uses the SCSI Select Utility to
control the SCSI controller board settings. If you order the SCSI model, you typically do not need to
configure the SCSI controller, because the utility will automatically recognize all SCSI devices connected to
it.
Run the SCSI Select Utility to verify or modify the SCSI controller settings, low-level format SCSI disks, or
verify SCSI media. Refer to “SCSI Configuration Utility” later in this chapter for further information.
CAUTION
You must not connect high voltage differential (HVD) SCSI devices on the SCSI bus or
you will damage the other LVD SCSI devices.
The single channel Ultra-160 PCI SCSI controller board provided with the SCSI model includes two SCSI
connectors and is normally installed in PCI slot P1. The SCSI cable provided has 5 connectors, (4 for SCSI
devices and 1 for the SCSI controller board) and one terminator on the end of the cable.
·
1 internal 68-pin connector – This internal connector is used to control the internal SCSI drives; up to a
total of four SCSI devices.
·
1 external 68-pin connector – This external SCSI connector is only used for external SCSI devices and
requires no additional internal cabling or switch settings. This connector supports up to 15 devices
connected to it externally.
NOTE
Only one 68-pin connector on the SCSI controller board can be used as the active SCSI
connector. Therefore, you cannot connect external SCSI devices to the external connector
when there are active internal SCSI devices connected to the internal SCSI connector.
22
Summary of Contents for Tc2110 - Server - 128 MB RAM
Page 1: ...HP Server tc2110 Operations and Maintenance Guide Online Version 1 10 December 2002 ...
Page 14: ......
Page 20: ......
Page 102: ......
Page 103: ...8 Parts Identification Exploded View Covers and Bezels 97 ...
Page 104: ...Chapter 8 Parts Identification Exploded View Mass Storage Devices 98 ...
Page 105: ...Chapter 8 Parts Identification Exploded View Chassis Fan Power Supply and System Board 99 ...
Page 106: ...Chapter 8 Parts Identification Exploded View System Board Components 100 ...
Page 110: ......
Page 114: ......