Step 3: Choose ProLiant Server(s)
Step 3: Choose ProLiant Server(s)
Step 3: Choose ProLiant Server(s)
Step 3: Choose ProLiant Server(s)
Server Compatibility
Server Compatibility
Server Compatibility
Server Compatibility
ML330 G2 (Direct Attached and RSO configurations only)
ML330 G3 (Direct Attached and RSO configurations only)
ML350 G2 (Direct Attached and RSO configurations only)
ML350 G3 (Clustering, Direct Attached and RSO configurations)
ML370 G2 (Clustering, Direct Attached and RSO configurations)
ML370 G3 (Clustering, Direct Attached and RSO configurations)
DL360 G2 (Clustering, Direct Attached and RSO configurations)
DL360 G3 (Clustering, Direct Attached and RSO configurations)
DL380 G2 (Clustering, Direct Attached and RSO configurations)
DL380 G3 (Clustering, Direct Attached and RSO configurations)
DL560 (Clustering, Direct Attached and RSO configurations)
DL580 (Clustering, Direct Attached and RSO configurations)
DL580 G2 (Clustering, Direct Attached and RSO configurations)
DL740 (Clustering and Direct Attached configurations)
DL760 (Clustering and Direct Attached configurations)
DL760 G2 (Clustering and Direct Attached configurations)
Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)
Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)
Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)
Step 4: Choose Host Connectivity (Skip If Purchased MSA500 Starter Kit)
Required for ML330 G2,
Required for ML330 G2,
Required for ML330 G2,
Required for ML330 G2,
ML350 G2, ML350 G3,
ML350 G2, ML350 G3,
ML350 G2, ML350 G3,
ML350 G2, ML350 G3,
ML370 G3, DL360 G2,
ML370 G3, DL360 G2,
ML370 G3, DL360 G2,
ML370 G3, DL360 G2,
DL360 G3, DL580, DL580
DL360 G3, DL580, DL580
DL360 G3, DL580, DL580
DL360 G3, DL580, DL580
G2, DL760
G2, DL760
G2, DL760
G2, DL760
Smart Array 532 Controller Option Kit
225338-B21
Required for ML370 G2
Required for ML370 G2
Required for ML370 G2
Required for ML370 G2
Smart Array 532 Controller
225338-B21
Smart Array 5i Controller Option Kit
226593-B21
NOTE:
NOTE:
NOTE:
NOTE: Either one Smart Array 532 Controller or one Smart Array 5i or Smart 5i Plus Controller
Option Kit is required.
Optional for DL380 G2
Optional for DL380 G2
Optional for DL380 G2
Optional for DL380 G2
Smart Array 532 Controller Option Kit
225338-B21
NOTE:
NOTE:
NOTE:
NOTE: The Smart Array 5i controller is included with the ProLiant DL380 G2. No additional
No additional
No additional
No additional
adapter required unless implementing Smart Array Multipath technology
adapter required unless implementing Smart Array Multipath technology
adapter required unless implementing Smart Array Multipath technology
adapter required unless implementing Smart Array Multipath technology
Optional for DL380 G3
Optional for DL380 G3
Optional for DL380 G3
Optional for DL380 G3
Smart Array 532 Controller Option Kit
225338-B21
NOTE:
NOTE:
NOTE:
NOTE: The Smart Array 5i Plus controller is included with the ProLiant DL380 G3. No additional
adapter required unless implementing Smart Array Multipath technology
QuickSpecs
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
HP StorageWorks Modular Smart Array 500
Configuration Information
DA - 11050 Canada — Version 13 — July 19, 2004