background image

The Modular Smart Array 500 utilizes a single, consistent set of utility software for storage and RAID management, setup, configuration and troubleshooting.
This consistency reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP server storage
solution.

Configuration Utilities

Configuration Utilities

Configuration Utilities

Configuration Utilities

Array Configuration Utility (ACU) [On-line for Microsoft and Linux, Remote Web-Based & Off-line]
Option ROM Configuration for Arrays (ORCA)

Management/Health

Management/Health

Management/Health

Management/Health
Utilities

Utilities

Utilities

Utilities

Insight Manager 7

Array Configuration

Array Configuration

Array Configuration

Array Configuration
Utility

Utility

Utility

Utility (ACU)

Provides a graphical view of HP drive array configurations.
Easy to use Wizards for configuration.
Web Based ACU supports On-Line, Remote Web Based and Off-line configuration.
Supports on-line configuration for Microsoft and Linux.
Configures Selective Storage Presentation (SSP).

Insight Manager 7

Insight Manager 7

Insight Manager 7

Insight Manager 7

Powerful storage, server and server option management tool.
Monitor storage from a remote central location.
Browser based Insight Manager 7 provides full access from anywhere on the Intranet, eliminating the need for a
dedicated Insight Manager console.

Supported Operating

Supported Operating

Supported Operating

Supported Operating
Systems

Systems

Systems

Systems

Microsoft Windows Server 2003 Web Edition
Microsoft Windows Server 2003 Standard Edition
Microsoft Windows Server 2003 Enterprise Edition
Microsoft Windows 2000 Server
Microsoft Windows 2000 Advanced Server
Microsoft Windows NT EE 4.0
Novell NetWare 5.1
Novell NetWare 6.0
Novell NetWare 6.5
Red Hat Linux 7.2, 7.3, 8.0
Red Hat Enterprise Linux 2.1
Red Hat Linux Advanced Server 2.1
UnitedLinux 1.0 (including SuSE Linux Enterprise Server 8)
SuSE Linux Enterprise Server 7 (SLES 7)
SCO OpenServer 5.0.5 and SCO OpenServer 5.0.6a

UnitedLinux = Conectiva Linux Enterprise Edition, SCO Linux 4.0, SuSE Linux Enterprise 8 and Turbolinux 8 all powered by
UnitedLinux 1.0
Not all configurations are supported on all operating systems; please refer to compatibility matrix

http://www.hp.com/products/sharedstorage

 for latest compatibility information.

QuickSpecs

HP StorageWorks Modular Smart Array 500

HP StorageWorks Modular Smart Array 500

HP StorageWorks Modular Smart Array 500

HP StorageWorks Modular Smart Array 500

Software Components

DA - 11050   Canada — Version 13 — July 19, 2004

Page 7

Summary of Contents for StorageWorks Modular Smart Array 500 System

Page 1: ...wer Indicators 4 SCSI Port B 2 Power Supply Blower Assemblies 5 SCSI I O Indicators 3 SCSI Port A 6 SCSI I O with Integrated Environmental Monitoring Unit EMU QuickSpecs HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array 500 Overview DA 11050 Canada Version 13 July 19 2004 Page 1 ...

Page 2: ... 4 ProLiant servers Redundant capable Smart Array Controllers with LCD screen to show system status messaging Total storage capacity of 2TB by using 14 HP Universal U320 Hard Disks of 146 8 GB each Multipath connectivity option with load balancing Redundant Power Supplies and Fans standard Fully convertible to HP StorageWorks Modular Smart Array 1000 RAID 0 1 1 0 5 and ADG standard Supports up to ...

Page 3: ...odule and installing a MSA 1000 FC I O module or MSA 1000 FC switch providing the customer with extended hardware investment protection into the future The Modular Smart Array 500 combines the array controller shelf and the drive shelf which holds up to fourteen 1 HP Universal Disk drives in a single 4U rack mount cabinet that s over 2 terabytes of storage Key Features Key Features Key Features Ke...

Page 4: ...ition to convertibility to the SAN the Modular Smart Array 500 allows the seamless migration of stored data in ProLiant servers protected by Smart Array PCI controllers to a Modular Smart Array 500 system Data that is currently stored on 1 Universal disk drives using HP Smart Array controllers as well as data on an RA4100 can easily be migrated to the Modular Smart Array 500 Simply remove the driv...

Page 5: ...ve server downtime single path configuration only Online Volume Extension allows for the capacity growth of existing logical volumes single path configuration only Logical Drive Capacity Extension allows the user to increase the size of existing logical drives online under Windows NT and offline for other operating systems Online Stripe Size Migration Allows changing stripe sizing of a logical dri...

Page 6: ... spares across different arrays Array Accelerator Onboard battery backed cache memory protects data in the event of a power failure In the unlikely event of a controller failure the battery backed cache will save critical user data for up to three days SCSI I O Module SCSI I O Module SCSI I O Module SCSI I O Module The I O module on the Modular Smart Array includes an integrated Environmental Moni...

Page 7: ...ement tool Monitor storage from a remote central location Browser based Insight Manager 7 provides full access from anywhere on the Intranet eliminating the need for a dedicated Insight Manager console Supported Operating Supported Operating Supported Operating Supported Operating Systems Systems Systems Systems Microsoft Windows Server 2003 Web Edition Microsoft Windows Server 2003 Standard Editi...

Page 8: ...h functionality and supports failover capabilities for redundant host bus adapters HBAs in a server with redundant cabling to a Modular Smart Array 500 This fault tolerance tool enhances availability of clustering and direct attached storage DAS solutions with up to two servers managing up to 2 TB of stored data When an HBA failure occurs the software moves the logical drives from the path of the ...

Page 9: ...0 expandable to five years HP Care Pack is defined as an upgrade to the product warranty attribute available for a specific duration and hours of coverage HP Care Pack is not available for less than the product s warranty duration HP Care Pack is available for sale anytime during the warranty period for most products but the commencement date will be the same as the Warranty Start Date delivery da...

Page 10: ...tep 2 Choose Modular Smart Array 500 System Options Step 2 Choose Modular Smart Array 500 System Options Options Options Options Options Modular Smart Array 500 High Availability Kit includes MSA500 controller 4 port IO Module Smart Array Multipath Software and 2 SA 532 Adapters 351281 B21 Modular Smart Array 500 Controller 218252 B21 4 Port Shared Storage Module with Smart Array Multipath Softwar...

Page 11: ...50 G3 ML350 G2 ML350 G3 ML350 G2 ML350 G3 ML370 G3 DL360 G2 ML370 G3 DL360 G2 ML370 G3 DL360 G2 ML370 G3 DL360 G2 DL360 G3 DL580 DL580 DL360 G3 DL580 DL580 DL360 G3 DL580 DL580 DL360 G3 DL580 DL580 G2 DL760 G2 DL760 G2 DL760 G2 DL760 Smart Array 532 Controller Option Kit 225338 B21 Required for ML370 G2 Required for ML370 G2 Required for ML370 G2 Required for ML370 G2 Smart Array 532 Controller 22...

Page 12: ...y Controller or U320 SCSI HBA to support U320 transfer rates NOTE NOTE NOTE NOTE For complete compatibility information refer to the HP SCSI Hard Drive Compatibility table located at http www compaq com products hdd hotplug html Step 7 Choose Rack Option Step 7 Choose Rack Option Step 7 Choose Rack Option Step 7 Choose Rack Option HP Rack 10000 Series HP Rack 10000 Series HP Rack 10000 Series HP R...

Page 13: ... SW Transceiver Kit 221470 B21 Modular Smart Array 30 Single Bus rack mountable 302969 B21 NOTE NOTE NOTE NOTE The MSA 1000 controller and the MSA 1000 Fibre Channel I O module or the MSA SAN Switch 2 8 are required for conversion To obtain conversion procedure document go to http www hp com go msa500 and download Converting Modular Smart Array 500 to a Modular Smart Array 1000 for Additional Scal...

Page 14: ...Input Voltage Rated Input Voltage Rated Input Voltage 100 to 240 VAC Rated Input Frequency Rated Input Frequency Rated Input Frequency Rated Input Frequency 50 to 60 Hz Rated Input Current Rated Input Current Rated Input Current Rated Input Current 2 3 A at12 VAC typical 6A Maximum Input Power Input Power Input Power Input Power max 549 W Heat Dissipation Heat Dissipation Heat Dissipation Heat Dis...

Page 15: ...le Firmware Upgradeable Firmware Upgradeable Firmware 2 MB flashable ROM Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Disk Drive and Enclosure Protocol Support Protocol Support Protocol Support Protocol Support Ulltra320 Ultra3 and Ultra2 SCSI 1 inch Universal drives Packaging Packaging Packaging Packaging Dimensions Dimensions Dimensions Dimensions L x W x D 14 5 x 1...

Page 16: ...the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein QuickSpecs HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array 500 HP StorageWorks Modular Smart Array ...

Reviews: