94
Event code reference
90
Informational The partner controller does not have a
mirrored configuration image for the current
controller, so the current controller’s local
flash configuration is being used. This event
is expected if the other controller is new or its
configuration has been cleared.
95
Critical
Both controllers in an active-active
configuration have the same serial number.
Non-unique serial numbers can cause system
problems; for example, vdisk ownership and
WWNs are determined by serial number.
A service technician must examine both
controller serial numbers and change at least
one of them.
96
Informational Pending configuration changes that take
effect at startup were ignored because
customer data might be present in cache.
If the requested configuration changes did
not occur, make the changes again and then
use a user-interface command to shut down
or restart the controller.
100
Informational During active-active operation, an event
(potential error) occurred while
communicating with the EMP, which reports
SES data.
101
Informational An update of EMP data has been triggered.
This event is for internal use only.
103
Informational Volume name change is complete.
104
Informational Volume size change is complete.
105
Informational Volume LUN change is complete.
106
Informational A volume has been added.
107
Critical
The controller experienced the specified
critical error. In a non-redundant
configuration the controller will be restarted
automatically. In an active-active
configuration the surviving controller will kill
the controller that experienced the critical
error.
A service technician can use the debug log
to determine the problem.
108
Informational A volume has been deleted.
109
Informational The statistics for the specified vdisk have
been reset.
110
Informational Ownership of the specified vdisk has been
given to the other controller.
111
Informational The link for the specified host port is up.
112
Informational
or warning
The link for the specified host port is down.
This event is logged as informational for
expected link-down events that happen
during controller startup. This event is logged
as a warning for unexpected link-down
events.
113
Informational The link for the specified disk channel port is
up.
114
Informational The link for the specified disk channel port is
down.
Table 14
Event code descriptions and recommended actions (continued)
Event
code
Event type
Description
Recommended action
Summary of Contents for StorageWorks 2000i
Page 8: ...8 ...
Page 10: ...10 ...
Page 28: ...28 Getting started ...
Page 66: ...66 Using system tools ...
Page 76: ...76 Viewing system status ...
Page 88: ...88 SNMP reference ...
Page 106: ...106 Event code reference ...
Page 112: ...112 Using FTP to download logs and update firmware ...