HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 111
6.
Quit the FTP session.
7.
If the updated disks must be power cycled:
a.
Shut down both controllers by using SMU.
b.
Power cycle all enclosures as described in your product’s user guide.
NOTE:
If you loaded firmware to a Seagate 750-Gbyte Barracuda ES SATA drive, after spin-up it
will be busy for about 50 seconds completing its upgrade. Then it will be ready for host I/O.
8.
In SMU, verify that each disk has the correct firmware revision.
9.
Resume host I/O.
Installing a license file
1.
Ensure that the license file is saved to a network location that the storage system can access.
2.
Open a Command Prompt (Windows) or a terminal window (UNIX) and navigate to the directory
containing the firmware file to load.
3.
Log in to the controller enclosure that the file was generated for:
ftp
controller-network-address
For example:
ftp 10.1.0.9
4.
Log in as an FTP user.
5.
Enter:
put
license-file
license
For example:
put certificate.txt license
A message confirms whether installation succeeded or failed. If installation succeeds, licensing
changes take effect immediately.
Summary of Contents for StorageWorks 2000i