80
SNMP reference
connUnitContact
Settable: Contact information for this
connectivity unit
Default: Uninitialized Contact
connUnitLocation
Settable: Location information for this
connectivity unit
Default: Uninitialized Location
connUnitEventFilter
Defines the event severity that will be
logged by this connectivity unit.
Settable only through SMU.
Default: info[8]
connUnitNumEvents
Number of events currently in the
connUnitEventTable
Varies as the size of the Event Table
varies
connUnitMaxEvents
Maximum number of events that can
be defined in the
connUnitEventTable
400
connUnitEventCurrID
Not supported
0
connUnitRevsTable
Includes the following objects as specified by the FA MIB2.2 Spec
connUnitRevsUnitId
connUnitId
of the connectivity unit
that contains this revision table
Same as
connUnitId
connUnitRevsIndex
Unique value for each
connUnitRevsEntry
between 1
and
connUnitNumRevs
See
External details for
connUnitRevsTable on page 83
connUnitRevsRevId
Vendor-specific string identifying a
revision of a component of the
connUnit
String specifying the code version.
Reports “Not Installed or Offline” if
module information is not available.
connUnitRevsDescription
Description of a component to which
the revision corresponds
See
External details for
connUnitRevsTable on page 83
connUnitSensorTable
Includes the following objects as specified by the FA MIB2.2 Spec
connUnitSensorUnitId
connUnitId
of the connectivity unit
that contains this sensor table
Same as
connUnitId
connUnitSensorIndex
Unique value for each
connUnitSensorEntry
between
1 and
connUnitNumSensors
See
External details for
connUnitSensorTable on page 84
connUnitSensorName
Textual identification of the sensor
intended primarily for operator use
See
External details for
connUnitSensorTable on page 84
connUnitSensorStatus
Status indicated by the sensor
ok[3], warning[4], or failed[5] as
appropriate for FRUs that are
present, or other[2] if FRU is not
present.
connUnitSensorInfo
Not supported
Empty string
connUnitSensorMessage
Description the sensor status as a
message
connUnitSensorName
followed
by the appropriate sensor reading.
Temperatures display in both Celsius
and Fahrenheit; for example, CPU
Temperature (Controller Module A):
48C 118F). Reports “Not installed”
or “Offline” if data is not available.
connUnitSensorType
Type of component being monitored
by this sensor
See
External details for
connUnitSensorTable on page 84
connUnitSensor
Characteristic
Characteristics being monitored by
this sensor
See
External details for
connUnitSensorTable on page 84
Table 10
FA MIB 2.2 objects, descriptions, and values (continued)
Object
Description
Value
Summary of Contents for StorageWorks 2000i
Page 8: ...8 ...
Page 10: ...10 ...
Page 28: ...28 Getting started ...
Page 66: ...66 Using system tools ...
Page 76: ...76 Viewing system status ...
Page 88: ...88 SNMP reference ...
Page 106: ...106 Event code reference ...
Page 112: ...112 Using FTP to download logs and update firmware ...