
5.
Read the controller LCD panel messages during the MSA startup routine.
• If the following messages are displayed, the serial number of the original chassis was
automatically transferred to the replacement chassis.
SPARE CHASSIS DETECTED
CHASSIS SERIAL NUMBER FLASHED UPDATED
IMPORTANT:
If these messages are displayed, the MSA1510i will automatically restart.
• If the following message is displayed, it may safely be ignored.
I2C WRITE FAILURE
• When the following message is displayed, the startup routine is complete.
STARTUP COMPLETE
Verifying proper operation
After replacing the failed chassis, verify that:
•
No error messages are displayed on the controller LCD panels.
•
The chassis Power LED is solid green.
•
The chassis Heartbeat LED is blinking green.
•
LEDs on each MSA module are showing a healthy status.
IMPORTANT:
If
CHASSIS MISMATCH POWER OFF AND FIX
is displayed on the controller LCD panel, persistent
data stored on all of the hard drives does not match. The original con
fi
guration was changed or startup
procedures were followed incorrectly. Power off the MSA1510i, correct any con
fi
guration changes,
and repeat the power-on sequence.
68
Customer replaceable components
Summary of Contents for StorageWorks 1510i - Modular Smart Array
Page 16: ...16 Specifications ...