Chapter 2
Installation
MP Core I/O Connections
38
If the CE Tool is a laptop using Reflection 1, check or change these communications settings using the
following procedure:
1. From the Reflection 1 Main screen, pull down the
Connection
menu and select
Connection Setup
.
2. Select
Serial Port
.
3. Select
Com1
.
4. Check the settings and change, if required.
Go to
More Settings
to set Xon/Xoff. Click
OK
to close the More Settings window.
5. Click
OK
to close the Connection Setup window.
6. Pull down the
Setup
menu and select
Terminal
(under the
Emulation
tab).
7. Select any HP terminal type.
Preferred types are
HP70092, HP70096
or
HP70094, HP70098, VT100
.
8. Click
Apply
.
This option is not highlighted if the terminal type you want is already selected.
9. Click
OK
.
Connecting the CE Tool to the Local RS-232 Port on the MP
This connection allows direct communications with the MP.
Only one window can be created
on the CE
Tool to monitor the MP. When enabled, it provides direct access to the MP and any partition.
Use the following procedure to connect the CE Tool to the Local RS-232 Port on the MP:
1. Connect one end of a null modem cable (9-pin to 9-pin) (Part Number 5182-4794) to the M cable connector
labeled CONSOLE.
2. Connect the other end of the RS-232 cable to the CE Tool.
Standby Power and Logging in to the MP
After connecting the serial device, it is possible to login to the Management Processor (MP). Housekeeping
power (also known as standby power) is generated as soon as AC power is applied to the server. Because the
MP uses standby power, it is possible to login to the MP even when the power switch is in the OFF position.
The power switch is a DC power switch that co48v DC.
Before powering up the hp rp7405/rp7410 server for the first time:
1. Verify that the AC voltage at the input source is within specifications for each hp rp7405/rp7410 being
installed.
2. If not already done so, power on the serial display device.
The preferred tool is the CE tool running Reflection 1.
To power up the MP, set up a communications link, and login to the MP:
1. Connect the server to AC power.
Summary of Contents for rp7405
Page 6: ...Contents vi ...
Page 8: ...Tables viii ...
Page 11: ...Preface ...
Page 15: ...xi Figure 1 Declaration of Conformity ...
Page 22: ...xviii ...
Page 39: ...Chapter 2 17 2 Installation ...
Page 70: ...Chapter 2 Installation Booting HP UX using Boot Console Handler BCH 48 ...
Page 71: ...Chapter 3 49 3 Troubleshooting ...
Page 78: ...Chapter 3 Troubleshooting Common Installation Problems 56 ...
Page 79: ...Chapter 4 57 4 Removal and Replacement ...
Page 111: ...Appendix A 89 A Replaceable Parts ...
Page 122: ...Appendix B System Specifications Environmental Specifications 100 ...
Page 123: ...Appendix C 101 C Site Preparation ...