Table C-1
Numeric Codes and Text Messages (continued)
Control panel message
Description
Recommended action
512-Chassis, Rear Chassis, or Front
Chassis Fan not Detected
Chassis, rear chassis, or front chassis fan is
not connected or may have malfunctioned.
1.
Reseat chassis, rear chassis, or front
chassis fan.
2.
Reseat fan cable.
3.
Replace chassis, rear chassis, or front
chassis fan.
514-CPU or Chassis Fan not Detected
CPU or chassis fan is not connected or may
have malfunctioned.
1.
Reseat CPU or chassis fan.
2.
Reseat fan cable.
3.
Replace CPU or chassis fan.
610-External Storage Device Failure
External tape drive not connected.
Reinstall tape drive or press
F1
and allow
system to reconfigure without the drive.
611-Primary Floppy Port Address
Assignment Conflict
Configuration error.
Run Computer Setup and check the
configuration in
Advanced
>
Onboard
Devices
.
660-Display cache is detected unreliable
Integrated graphics controller display cache
is not working properly and will be disabled.
Replace system board if minimal graphics
degrading is an issue.
912-Computer Cover Has Been Removed
Since Last System Startup
Computer cover was removed since last
system startup.
No action required.
917-Front Audio Not Connected
Front audio harness has been detached or
unseated from motherboard.
Reconnect or replace front audio harness.
918-Front USB Not Connected
Front USB harness has been detached or
unseated from motherboard.
Reconnect or replace front USB harness.
921-Device in PCI Express slot failed to
initialize
There is an incompatibility/problem with this
device and the system or PCI Express Link
could not be retrained to an x1.
Try rebooting the system. If the error
reoccurs, the device may not work with this
system
1151-Serial Port A Address Conflict
Detected
Both external and internal serial ports are
assigned to COM1.
1.
Remove any serial port expansion
cards.
2.
Clear CMOS.
3.
Reconfigure card resources and/or run
Computer Setup or Windows utilities.
1152-Serial Port B Address Conflict
Detected
Both external and internal serial ports are
assigned to COM2.
1.
Remove any serial port expansion
cards.
2.
Clear CMOS.
3.
Reconfigure card resources and/or run
Computer Setup or Windows utilities.
1155-Serial Port Address Conflict Detected
Both external and internal serial ports are
assigned to same IRQ.
1.
Remove any serial port expansion
cards.
2.
Clear CMOS.
3.
Reconfigure card resources and/or run
Computer Setup or Windows utilities.
1201-System Audio Address Conflict
Detected
Device IRQ address conflicts with another
device.
Enter Computer Setup and reset the IRQ in
Advanced
>
Onboard Devices
.
122 Appendix C POST Error Messages